Key result
Ultimaster stent matches Xience with ~96% freedom from target lesion failure at 9 months.
Why the study?
Does the Ultimaster biodegradable-polymer sirolimus-eluting stent provide similar efficacy and safety compared to contemporary new-generation DES in patients undergoing coronary stenting?
Does the Ultimaster biodegradable-polymer sirolimus-eluting stent provide similar efficacy and safety compared to contemporary new-generation DES in patients undergoing coronary stenting?
The Ultimaster biodegradable-polymer sirolimus-eluting stent demonstrates comparable efficacy and safety to contemporary new-generation drug-eluting stents.
Answers are grounded in this paper and cite their sources.
Supports comparable stent options in PCI; extends CENTURY II data across subsets but leaves long-term adoption open.
The Ultimaster coronary stent system (Terumo Corporation, Tokyo, Japan) represents a new iteration in drug-eluting stent (DES) technology that has recently received the Conformité Européenne (CE) mark approval for clinical use. The Ultimaster is a thin-strut, cobalt chromium, biodegradable-polymer, sirolimus-eluting coronary stent. The high elasticity of the biodegradable-polymer (PDLLA-PCL) and the abluminal gradient coating technology are additional novel features of this coronary device. The Ultimaster DES has undergone extensive clinical evaluation in two studies: The CENTURY I and II trials. Results from these two landmark studies suggested an excellent efficacy and safety profile of the Ultimaster DES across several lesion and patient subsets, with similar clinical outcomes to contemporary, new-generation DES. The aim of this review is to summarize the rationale behind this novel DES technology and to provide an update of available evidence about the clinical performance of the Ultimaster DES.
No takes yet. Share an insight, caveat, or question.
Chisari et al. (2016) conducted a review in Ischemic heart disease (n=1,119). Ultimaster biodegradable-polymer sirolimus-eluting stent vs. Permanent-polymer everolimus-eluting stent (Xience EES) was evaluated on Freedom from Target Lesion Failure (TLF) at 9 months (absolute risk difference of 0.55%, p=<0.0001 for non-inferiority). In the highlighted CENTURY II trial, the Ultimaster biodegradable-polymer sirolimus-eluting stent demonstrated noninferiority to the Xience everolimus-eluting stent, with freedom from target lesion failure at 9 months.
Synapse has enriched 10 related papers. Consider them for comparative context: