Key result
Smartphone-case cuffless monitor matches standard sphygmomanometer SBP with ~0.3 mmHg difference.
Why the study?
Simple, accurate, and affordable cuffless blood pressure devices could enhance compliance with measurement recommendations and telemonitoring, prompting evaluation of a smartphone-case ECG and photoplethysmography device in hypertensive patients.
Does a smartphone-case based ECG monitor with PPG accurately measure blood pressure compared to a conventional sphygmomanometer in hypertensive patients?
Cohort (n=500)
No
Does a smartphone-case based ECG monitor with PPG accurately measure blood pressure compared to a conventional sphygmomanometer in hypertensive patients?
A smartphone-case based cuffless blood pressure monitor using ECG and PPG demonstrated strong correlation with conventional sphygmomanometry, highlighting its potential for accessible BP telemonitoring.
Answers are grounded in this paper and cite their sources.
May support cuffless BP telemonitoring in hypertension; leaves open prospective validation before clinical adoption.
The availability of simple, accurate, and affordable cuffless blood pressure (BP) devices has the potential to greatly increase the compliance with measurement recommendations and the utilization of BP measurements for BP telemonitoring. The aim of this study is to evaluate the correlation between findings from routine BP measurements using a conventional sphygmomanometer with the results from a portable ECG monitor combined with photoplethysmography (PPG) for pulse wave registration in patients with arterial hypertension. Methods: The study included 500 patients aged 32–88 years (mean 64 ± 7.9 years). Mean values from three routine BP measurements by a sphygmomanometer with cuff were selected for comparison; within one minute after the last measurement, an electrocardiogram (ECG) was recorded for 3 min in the standard lead I using a smartphone-case based single-channel ECG monitor (CardioQVARK®-limited responsibility company “L-CARD”, Moscow, Russia) simultaneously with a PPG pulse wave recording. Using a combination of the heart signal with the PPG, levels of systolic and diastolic BP were determined based on machine learning using a previously developed and validated algorithm and were compared with sphygmomanometer results. Results: According to the Bland–Altman analysis, SD for systolic BP was 3.63, and bias was 0.32 for systolic BP. SD was 2.95 and bias was 0.61 for diastolic BP. The correlation between the results from the sphygmomanometer and the cuffless method was 0.89 (p = 0.001) for systolic and 0.87 (p = 0.002) for diastolic BP. Conclusion: Blood pressure measurements on a smartphone-case without a cuff are encouraging. However, further research is needed to improve the accuracy and reliability of clinical use in the majority of patients.
No takes yet. Share an insight, caveat, or question.
Sagirova et al. (2021) conducted a cohort in Arterial hypertension (n=500). Smartphone-case based ECG monitor with photoplethysmography (CardioQVARK) vs. Cuff-based sphygmomanometer was evaluated on Mean difference in systolic blood pressure between cuffless device and sphygmomanometer (MD 0.32, 95% CI 0.003-0.64, p=0.048). The smartphone-case based cuffless monitor showed strong correlation and a minimal mean difference of 0.32 mm Hg for systolic blood pressure compared to a traditional cuff sphygmomanometer.