Key result
AALARA registry evaluates radiation exposure with routine EnSite Precision 3D mapping during SVT ablation.
Why the study?
Real-world data and outcome generalisability for minimal fluoroscopic catheter ablation of supraventricular arrhythmias remain scarce outside the USA and Western Europe.
Does the routine use of a 3D mapping system reduce ionising radiation exposure in patients undergoing catheter ablation for right-sided supraventricular arrhythmias?
Observational (n=700)
Open-label
Yes
Does the routine use of a 3D mapping system reduce ionising radiation exposure in patients undergoing catheter ablation for right-sided supraventricular arrhythmias?
This study protocol outlines a multinational registry to evaluate the real-world radiation exposure, safety, and efficacy of using a 3D mapping system for minimal fluoroscopy ablation of right-sided supraventricular arrhythmias.
Supports evaluation of 3D mapping for radiation reduction in right-sided SVT; leaves open routine adoption pending completed registry data.
INTRODUCTION: The reduction of fluoroscopic exposure during catheter ablation of supraventricular arrhythmias is widely adopted by experienced electrophysiology physicians with a relatively short learning curve and is becoming standard of care in many parts of the world. While observational studies in the USA and some parts of Western Europe have evaluated the minimal fluoroscopic approach, there are scarce real-world data for this technique and generalisability of outcome in other economic regions. METHODS AND ANALYSIS: The arrhythmias with as low as reasonably achievable X-ray exposure study is a prospective, observational, multicentre and multinational open-label registry study. Up to 700 patients undergoing catheter ablation for right-sided supraventricular arrhythmias (according to national guidelines) will be enrolled for the routine use of the EnSite Precision 3D mapping system. Participating sites are distributed in 13 countries from Central Eastern Europe, North and South Africa, the Middle East and the CIS (Commonwealth of Independent States), with different levels of expertise using minimal fluoroscopic exposure techniques. After electrophysiological procedure, patients will be followed up for 6 months either in-clinic or via telephone interview. Patients will be asked to complete a study questionnaire at enrolment and 6 months after the invasive procedure to assess quality of life changes secondary to the procedure. The study's primary objective is to describe ionising radiation exposure during catheter ablation when the EnSite Precision 3D mapping system is used in supraventricular tachycardia ablation. The study's secondary objective is to assess the safety and efficacy of this method. Furthermore, fluoroscopy timing, total procedure time, success rate and complications will be reported. ETHICS AND DISSEMINATION: The study was approved by the ethics committee at Mohammed Bin Khalifa Specialist Cardiac Centre (BDF/R&REC/2020-504) and the medical ethics committees of all participating sites. Participants will be required to provide informed consent before enrolment in the study. The study results will be published and presented at conferences. TRIAL REGISTRATION NUMBER: NCT04716270.
No takes yet. Share an insight, caveat, or question.
Szegedi et al. (2023) conducted an observational in Right-sided supraventricular tachycardia (SVT) (n=700). EnSite Precision 3D mapping system was evaluated on Ionising radiation exposure during transcatheter ablation of SVT. The AALARA study is an ongoing prospective observational registry protocol to evaluate ionizing radiation exposure during routine use of EnSite Precision 3D mapping for right-sided SVT ablation.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: