Key result
Fluoroscopy-free ablation of right accessory pathways using a three-dimensional navigation system was successful and without complications in 95% of pediatric patients.
Why the study?
Does a fluoroscopy-free, single-catheter approach using 3D navigation achieve successful and safe ablation in pediatric patients with right accessory pathways?
Observational (n=21)
Does a fluoroscopy-free, single-catheter approach using 3D navigation achieve successful and safe ablation in pediatric patients with right accessory pathways?
Fluoroscopy-free radiofrequency ablation of right accessory pathways in children using a 3D navigation system and a single-catheter approach is feasible, safe, and highly successful.
Answers are grounded in this paper and cite their sources.
May reduce fluoroscopy exposure in pediatric right AP ablation; leaves open need for randomized trials before practice change.
INTRODUCTION: The field of pediatric electrophysiology poses many challenges to electrophysiologists. In particular there are two major concerns: (1) to reduce the amount of fluoroscopy exposure to patients and medical staff in the catheterization laboratory and (2) to minimize the number of vascular accesses. Prolonged fluoroscopy times are associated with radiofrequency (RF) ablation of right accessory pathways (APs), particularly the right free-wall AP. The aim of this study was to eliminate the use of fluoroscopy during treatment of right-sided APs in children while using a single-catheter approach. METHODS AND RESULTS: We studied 21 consecutive pediatric patients (mean age 11.3 +/- 3.2 years) with Wolff-Parkinson-White syndrome due to a right AP. To limit fluoroscopy use, we used a three-dimensional navigation system that facilitated reconstruction of a three-dimensional electroanatomic activation map along the tricuspid annulus either on the atrial side during orthodromic AV reciprocating tachycardia or along the ventricular side during anterograde preexcitation. RF application was successful and without complications in 20 patients (success rate 95%); moreover, 19 of the 21 patients underwent a single-catheter procedure. The remaining two patients required an additional quadripolar catheter for atrial stimulation. A mean of 2 +/- 1 RF applications were used during the whole study. CONCLUSION: Our study demonstrates that ablation of right APs in children can be performed without fluoroscopy using a single catheter with minimal amounts of RF applications. Our new technique is associated with high success rates.
No takes yet. Share an insight, caveat, or question.
Drago et al. (2002) conducted an observational in Wolff-Parkinson-White syndrome due to a right accessory pathway (n=21). Fluoroscopy-free ablation using a three-dimensional navigation system was evaluated on Successful radiofrequency application without complications. Fluoroscopy-free ablation of right accessory pathways using a three-dimensional navigation system was successful and without complications in 95% of pediatric patients.
Synapse has enriched 10 related papers. Consider them for comparative context: