Key result
Contrast-enhanced coronary vessel wall MRI at 3.0 Tesla significantly improved image quality compared to 1.5 Tesla (median score 3 vs 2, p=0.019) and demonstrated 91% accuracy for detecting CAV.
Why the study?
Does contrast-enhanced coronary vessel wall imaging at 3.0 Tesla improve image quality and diagnostic accuracy for coronary allograft vasculopathy compared to 1.5 Tesla in post-transplant adolescents?
RCT (n=24)
Randomized
Does contrast-enhanced coronary vessel wall imaging at 3.0 Tesla improve image quality and diagnostic accuracy for coronary allograft vasculopathy compared to 1.5 Tesla in post-transplant adolescents?
Answers are grounded in this paper and cite their sources.
Contrast-enhanced coronary vessel wall MRI at 3.0 Tesla provides improved image quality and accurate non-invasive quantification of coronary allograft vasculopathy compared to 1.5 Tesla.
Coronary Allograft Vasculopathy (CAV) remains the leading cause of late death after heart transplantation in children but is poorly detected by X-ray angiography. Intravascular ultrasound (IVUS) is invasive and costly, which precludes close follow-up. We have previously demonstrated the feasibility of MRI late gadolinium enhancement (LGE) in the coronary vessel wall to detect and grade CAV. The purpose of this study was to demonstrate the clinical utility of the technique and if it could be improved by imaging at 3.0 Tesla. Participants underwent IVUS and cardiac MRI. Maximal intimal thickness (MIT), mean intimal index (MII = mean intimal area/ mean vessel area) and Stanford grade (0 to 4(severe)) were recorded on IVUS. MRI included a coronary magnetic resonance angiogram (CMRA) of the left coronary artery and LGE vessel wall imaging after administration of 0.2 mmol/kg Gadolinium. Participants were randomised to 3T or 1.5T (Achieva, Philips Healthcare, Best, Netherlands). 32-element cardiac phased-array receiver coils were used. The mean enhancement diameter (ED) and index (Ei= mean enhancement area/ mean vessel area on MRI) was quantified on LGE images fused with CMRA as a roadmap. Additionally, images were scored for inter/intra-observer error in analysis and image quality (0 (not seen) to 4 (sharp image)). Location of LGE on MRI and location of significant intimal thickening on IVUS were also recorded for comparison. 24 adolescents participated in the study (characteristics: Table 1 ). One MRI failed due to patient discomfort. Overall, there was excellent correlation of MRI with IVUS. Pearson’s correlation for ED with MIT was 0.80 (p<0.001) and for Ei with MII was 0.92 (p<0.001). Correlation coefficients at 3T were similar to 1.5T (0.77 & 0.96 versus 0.81 & 0.62 respectively (all p<0.05)). Bland-Altman analysis also shows similar inter/intra-observer agreement between the two field strengths. However, LGE image quality was improved at 3T (median=3) compared to 1.5T (median=2; p=0.019 by Mann-Whitney test). Furthermore, at 1.5T only 11 out of 17 areas of enhancement on MRI were associated with corresponding significant disease on IVUS (i.e. location match to within 1mm from a major branch-point). At 3T, however, 11 of 13 enhancing lesions had exact and anatomical match (Figure 1 ). A) Patient 1 Left Coronary system CMRA at 3T. B) Patient 1 LGE at 3T. C) Patient 2 Left Coronary CMRA at 1.5T. D) Patient 2 LGE at 1.5T E) Overlay of Patient 1 LGE on CMRA at 3T. Arrows show corresponding positions for IVUS pictures G & H. F) Overlay of Patient 2 LGE on CMRA at 1.5T. Arrows show corresponding positions for IVUS pictures I & J. G & I) IVUS images. White box illustrates intimal thickening corresponding to enhancement on overlay picture above J & H) IVUS images. No significant intimal thickening corresponding to areas without enhancement on overlay picture above Overall, the receiver operating characteristics curve demonstrates that a cut-off of 7.5 mm ED on MRI has 86% sensitivity and 94% specificity for the detection of significant (Stanford grade 4 on IVUS) CAV. This gives a positive predictive value of 86%, negative predictive value of 94% and accuracy of 91%. In the multivariate analysis, donor age, length of time post transplant and MRI (ED) were the only significant independent predictors of maximum intimal thickness on IVUS. Coronary vessel wall delayed enhancement MRI is a valuable and accurate non-invasive method to quantify CAV. Improved image quality at 3.0 Tesla further ameliorates the accuracy of this technique.
No takes yet. Share an insight, caveat, or question.
Hussain et al. (2012) conducted an RCT in Coronary Allograft Vasculopathy (CAV) (n=24). Contrast-enhanced coronary vessel wall MRI at 3.0 Tesla vs. 1.5 Tesla MRI was evaluated on Late gadolinium enhancement (LGE) image quality score (0 to 4) (p=0.019). Contrast-enhanced coronary vessel wall MRI at 3.0 Tesla significantly improved image quality compared to 1.5 Tesla (median score 3 vs 2, p=0.019) and demonstrated 91% accuracy for detecting CAV.