Key result
Covalently bound Gd-DTPA contrast increases vein graft MRI signal-to-noise ratio ~73% in preclinical imaging.
Why the study?
Non-invasive monitoring of autologous vein graft bypass grafts is limited to detecting late luminal narrowing, and MRI scan times for sufficient resolution are currently impractical.
Does a covalently attached Gd-DTPA-based contrast agent improve MRI visualization of arterial bypass vein grafts in a mouse model?
Does a covalently attached Gd-DTPA-based contrast agent improve MRI visualization of arterial bypass vein grafts in a mouse model?
A covalently bound Gd-DTPA contrast agent significantly enhances early MRI visualization of vein grafts in a mouse model, though signal durability requires further optimization.
Answers are grounded in this paper and cite their sources.
May enable faster MRI of vein grafts in animal models; leaves open clinical translation for early failure detection.
Background Non-invasive monitoring of autologous vein graft (VG) bypass grafts is largely limited to detecting late luminal narrowing. Although magnetic resonance imaging (MRI) delineates vein graft intima, media, and adventitia, which may detect early failure, the scan time required to achieve sufficient resolution is at present impractical. Purpose To study VG visualization enhancement in vivo and delineate whether a covalently attached MRI contrast agent would enable quicker longitudinal imaging of the VG wall. Material and Methods Sixteen 12-week-old male C57BL/6J mice underwent carotid interposition vein grafting. The inferior vena cava of nine donor mice was treated with a gadolinium-diethylenetriaminepentaacetic acid (Gd-DTPA)-based contrast agent, with control VGs labeled with a vehicle. T1-weighted (T1W) MRI was performed serially at postoperative weeks 1, 4, 12, and 20. A portion of animals was sacrificed for histopathology following each imaging time point. Results MRI signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were significantly higher for treated VGs in the first three time points (1.73 × higher SNR, P = 0.0006, and 5.83 × higher CNR at the first time point, P = 0.0006). However, MRI signal enhancement decreased consistently in the study period, to 1.29 × higher SNR and 2.64 × higher CNR, by the final time point. There were no apparent differences in graft morphometric analyses in Masson's trichrome-stained sections. Conclusion A MRI contrast agent that binds covalently to the VG wall provides significant increase in T1W MRI signal with no observed adverse effects in a mouse model. Further optimization of the contrast agent to enhance its durability is required.
No takes yet. Share an insight, caveat, or question.
Mitsouras et al. (2018) studied Carotid interposition vein grafting (n=16). Gadolinium-diethylenetriaminepentaacetic acid (Gd-DTPA)-based contrast agent vs. Vehicle was evaluated on MRI signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) (1.73 × higher SNR and 5.83 × higher CNR, p=0.0006). A covalently bound Gd-DTPA-based MRI contrast agent significantly increased T1-weighted MRI signal-to-noise ratio (1.73x higher, P=0.0006) in a mouse vein graft model.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: