Key result
VT induced by a second PVS after a negative first PVS was associated with a 38.3% rate of death or arrhythmia at 3 years, compared to 20.9% for first PVS (P=0.042).
Why the study?
Does a second programmed ventricular stimulation (PVS) predict death or arrhythmia in post-MI patients with LVEF ≤ 40% when the first PVS is negative?
Cohort (n=290)
Does a second programmed ventricular stimulation (PVS) predict death or arrhythmia in post-MI patients with LVEF ≤ 40% when the first PVS is negative?
Absolute Event Rate: 38.3% vs 20.9%
p-value: p=0.042
A second programmed ventricular stimulation during EPS identifies a significant proportion of high-risk post-MI patients who would otherwise be missed by a single stimulation.
BACKGROUND: The prognostic significance of a second programmed ventricular stimulation (PVS) at electrophysiology study (EPS), when the first PVS is negative for inducible ventricular tachycardia (VT), in patients following myocardial infarction (MI) is unknown. METHODS: Consecutive ST-elevation MI patients with left ventricular ejection fraction ≤ 40% following revascularization underwent early EPS. An implantable cardioverter defibrillator (ICD) was implanted for a positive (inducible monomorphic VT) but not a negative (no arrhythmia or inducible ventricular fibrillation [VF]/flutter) EPS. The combined primary end point of death or arrhythmia (sudden death, resuscitated cardiac arrest, and spontaneous VT/VF) was assessed in EPS-positive patients grouped according to if VT was induced on the first PVS application, or the second PVS application, when the first was negative. RESULTS: EPS performed a median 8 days post-MI in 290 patients was negative in 70% (n = 203) and positive in 30% (n = 87). In patients with a positive EPS, VT was induced on the first PVS in 67% (n = 58) and the second PVS, after the first was negative, in 33% (n = 29). Predischarge ICD was implanted in 79 of 87 patients with a positive EPS. Three-year primary end point occurred in 20.9 ± 5.6% and 38.3 ± 9.7% of patients with VT induced by the first and second PVS, respectively (P = 0.042) and in 6.3 ± 1.9% of electrophysiology-negative patients (P < 0.001). CONCLUSIONS: In patients with post-MI left ventricular dysfunction, VT can be induced in a significant proportion with a second PVS when negative on the first. These patients have a similar higher risk of death or arrhythmia compared to patients with VT induced on the first PVS.
No takes yet. Share an insight, caveat, or question.
Zaman et al. (2014) conducted a cohort in ST-elevation myocardial infarction with left ventricular dysfunction (n=290). Second programmed ventricular stimulation (PVS) inducing VT vs. First PVS inducing VT was evaluated on Death or arrhythmia (sudden death, resuscitated cardiac arrest, and spontaneous VT/VF) (p=0.042). VT induced by a second PVS after a negative first PVS was associated with a 38.3% rate of death or arrhythmia at 3 years, compared to 20.9% for first PVS (P=0.042).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: