Key result
Endovascular abdominal aortic aneurysm repair with first-generation stent grafts resulted in an 8-year cumulative conversion-free and rupture-free survival of 48.0%.
Why the study?
What are the long-term outcomes and complication rates of elective endovascular abdominal aortic aneurysm repair using first-generation stent grafts?
Observational (n=1,190)
Yes
What are the long-term outcomes and complication rates of elective endovascular abdominal aortic aneurysm repair using first-generation stent grafts?
Patients treated with first-generation stent grafts for abdominal aortic aneurysms have a considerable risk of late complications, highlighting the need for lifelong surveillance.
Answers are grounded in this paper and cite their sources.
Warrants lifelong surveillance after first-generation EVAR; leaves open durability of modern stent grafts.
HYPOTHESIS: Little information about the long-term results of endovascular abdominal aortic aneurysm repair is available. This study was performed to evaluate the long-term data of patients treated with the first generation of commercially available stent grafts. DESIGN: Multicenter registry. SETTING: Sixty-two European centers that participated in the EUROSTAR (EUROpean collaborators on Stent-graft Techniques for abdominal aortic Aneurysm Repair) registry. PATIENTS: A total of 1190 patients with a follow-up of up to 8 years, who underwent endovascular abdominal aortic aneurysm repair with a stent graft (Stentor or Vanguard). INTERVENTION: Elective endovascular abdominal aortic aneurysm repair. MAIN OUTCOME MEASURES: The morbidity and mortality data of patients treated with the first-generation stent graft who enrolled in the EUROSTAR registry were analyzed. Incidence rates of complications were calculated to quantify annual risks. Life-table analyses and multivariate Cox proportional hazards models were used for the survival analysis. RESULTS: Conversion to open repair, aneurysm rupture, all-cause death, and aneurysm-related death occurred in 7.1%, 2.4%, 19.9%, and 3.0% of the patients, respectively. The cumulative percentage of the combined outcome event, conversion-free and rupture-free survival, after 8 years was 48.0%. Procedure-related complications that frequently occurred were endoleak (13.0 cases per 100 patient-years), stenosis/thrombosis (4.6 cases per 100 patient-years), and stent migration (4.3 cases per 100 patient-years). CONCLUSIONS: Patients treated with the first generation of stent grafts will need lifelong surveillance because of a considerable risk of late complications. How these findings translate to the outcome of newer-generation stent grafts is unknown. For this reason, vigilant surveillance remains indicated in all patients who undergo endovascular abdominal aortic aneurysm repair.
No takes yet. Share an insight, caveat, or question.
Lina J. Leurs (2007) conducted an observational in Abdominal aortic aneurysm (n=1,190). Endovascular abdominal aortic aneurysm repair with first-generation stent grafts was evaluated on Combined outcome event (conversion-free and rupture-free survival) after 8 years. Endovascular abdominal aortic aneurysm repair with first-generation stent grafts resulted in an 8-year cumulative conversion-free and rupture-free survival of 48.0%.