Key result
Isometric handgrip exercise significantly increased pulse wave velocity (from 10.03 to 11.09 m/s) and augmentation index only in patients with coronary artery disease, unmasking arterial stiffness not evident at rest.
Why the study?
Does isometric handgrip exercise reveal increased arterial stiffness in patients with coronary artery disease compared to those without?
Cross-Sectional (n=42)
No
Does isometric handgrip exercise reveal increased arterial stiffness in patients with coronary artery disease compared to those without?
Isometric handgrip exercise unmasks increased arterial stiffness in patients with coronary artery disease that is not evident at rest.
Handgrip exercise may unmask arterial stiffness differences in CAD; hypothesis-generating and requires prospective validation before clinical use.
BACKGROUND: Arterial stiffness of patients with coronary artery disease (CAD), which is expected to be increased due to a generalized atherosclerotic process of human body, may be more evident after the acute increase of blood pressure (BP) or peripheral vascular resistance. Isometric handgrip exercise is a simple and easily applicable method to achieve this goal. We investigated the changes of hemodynamic parameters and arterial stiffness indexes after handgrip exercise in patients with CAD. METHODS: Forty-two subjects, who underwent coronary angiography (CAG), were enrolled. After CAG, baseline arterial waveforms were traced at the aortic root and external iliac artery using right coronary catheters. Arterial waveforms were recorded at 1, 2, and 3 min in the aortic root and at 3 min in the external iliac artery after isometric handgrip exercise at 30% ~ 40% of the maximal handgrip power. Augmentation pressure (AP) and augmentation index (AIx) were measured at aortic pressure waveforms. Pulse wave velocity (PWV) was calculated using the ECG-gated time difference of the upstroke of arterial waveforms and the distance between the aortic root and the external iliac artery. RESULTS: Thirty patients had CAD (CAD group), and others showed no significant coronary stenosis (non-CAD group). Baseline hemodynamic parameters including AIx and PWV were not different between both groups. After isometric handgrip exercise, central systolic blood pressure (BP), central diastolic BP, central pulse pressure, peripheral systolic BP, and peripheral pulse pressure were increased in all patients. AIx inclined significantly from 1 min after exercise only in patients with CAD (before 17.7% ± 9.7% vs. 3 min after exercise 22.3% ± 10.7%, p < 0.001). PWV also increased significantly after exercise only in patients with CAD (before 10.03 ± 1.99 m/s vs. 3 min after 11.09 ± 2.45 m/s, p < 0.001). CONCLUSIONS: Arterial stiffness indexes at rest were not different between patients with and without CAD. After isometric handgrip exercise, increased arterial stiffness became evident only in patients with CAD.
No takes yet. Share an insight, caveat, or question.
Moon et al. (2015) conducted a cross-sectional in Coronary artery disease (n=42). Isometric handgrip exercise vs. Baseline (rest) and non-CAD patients was evaluated on Pulse wave velocity (PWV) at 3 minutes in CAD patients (p=<0.001). Isometric handgrip exercise significantly increased pulse wave velocity (from 10.03 to 11.09 m/s) and augmentation index only in patients with coronary artery disease, unmasking arterial stiffness not evident at rest.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: