Key result
Intracardiac echocardiography guidance for edge-to-edge transcatheter tricuspid valve repair resulted in a 0% procedural complication rate, identical to TEE alone.
Why the study?
TEE guidance for edge-to-edge transcatheter tricuspid valve repair with MitraClip may not offer sufficient image quality in a significant proportion of patients.
Does intracardiac echocardiography (ICE) guidance improve procedural success and safety in patients undergoing edge-to-edge transcatheter tricuspid valve repair with insufficient TEE quality?
Observational (n=11)
No
Does intracardiac echocardiography (ICE) guidance improve procedural success and safety in patients undergoing edge-to-edge transcatheter tricuspid valve repair with insufficient TEE quality?
Answers are grounded in this paper and cite their sources.
Intracardiac echocardiography is a safe and feasible adjunctive imaging tool that enables successful transcatheter tricuspid valve repair in patients with inadequate transesophageal echocardiography imaging.
BACKGROUND: Transesophageal echocardiography (TEE) as a guiding tool for edge-to-edge transcatheter tricuspid valve repair (EETVr) using MitraClip (Abbott Vascular, Santa Clara, USA) may not offer sufficient image quality in a significant proportion of patients. OBJECTIVES: Intracardiac echocardiography (ICE) as additional guiding tool in EETVr with the MitraClip device. METHODS: Appropriate angulations of the ICE catheter to visualize each commissure of the tricuspid valve were established in 3D printed heart models. In a single tertiary-care center ICE was used to support EETVr as additional guidance when TEE image quality was insufficient. Procedural safety and outcomes up to 30-days were compared between ICE/TEE and TEE only guided patients. RESULTS: In 6 of 11 patients (54.5%) undergoing EETVr with MitraClip TEE alone was unsatisfactory, necessitating additional ICE guidance. In 4 of these 6 patients ICE enabled a successful completion of the procedure. The steering maneuvers identified in the 3D models were well applicable in all patients, providing examples for potential future ICE implementation in EETVr. Under both TEE alone (n = 5) and ICE (n = 6) guidance the rate of procedural complications was 0%. According to vena contracta values at discharge significant TR reduction was achievable in the treated cohort (p = 0.011). At 30-days follow-up one patient (ICE guided) died following global heart failure, not associated with the procedure itself. CONCLUSIONS: ICE guidance may offer an additional tool to guide EETVr with the MitraClip device in patients with poor TEE quality, as it enables successful results without impairing procedural safety.
No takes yet. Share an insight, caveat, or question.
Curio et al. (2020) conducted an observational in Tricuspid regurgitation (n=11). Intracardiac echocardiography (ICE) guidance vs. Transesophageal echocardiography (TEE) alone was evaluated on Procedural complications. Intracardiac echocardiography guidance for edge-to-edge transcatheter tricuspid valve repair resulted in a 0% procedural complication rate, identical to TEE alone.
Synapse has enriched 10 related papers. Consider them for comparative context: