Key result
Unenhanced CT attenuation values were highly correlated with chemical-shift ratios at MR imaging in evaluating adrenal masses (correlation 0.85, P<0.000001).
Why the study?
Does CT attenuation correlate with MRI chemical-shift ratio in evaluating adrenal masses?
Cross-Sectional (n=38)
Does CT attenuation correlate with MRI chemical-shift ratio in evaluating adrenal masses?
Effect estimate: Correlation 0.85
p-value: p=< .000001
CT attenuation values are highly correlated with chemical-shift ratios on MRI for evaluating adrenal masses, with both modalities being indeterminate for a similar subset of benign lesions.
CT-MR correlation may aid adrenal lesion characterization; leaves open prospective validation before practice change.
PURPOSE: To correlate attenuation values at computed tomography (CT) with signal intensity at chemical-shift magnetic resonance (MR) imaging in adrenal masses. MATERIALS AND METHODS: Thirty-eight patients with 47 adrenal lesions underwent MR imaging and unenhanced CT examinations. MR examinations, performed at 1.5 T, included T1-weighted imaging with fat and water in phase and gradient-echo imaging with fat and water out of phase (repetition time, 45-180 msec; echo time, 1.4-3.1 msec). Lesion-to-spleen signal intensity ratios were calculated for the in-phase and opposed-phase images. The chemical-shift ratio, a measure of signal intensity loss between in-phase and opposed-phase images, and the CT attenuation value (in Hounsfield units) were determined for each lesion. RESULTS: A statistically significant correlation (0.85) was found between attenuation and chemical-shift-ratio values (P < .000001). Attenuation in six benign lesions was within 2 standard deviations of the mean attenuation in malignant lesions, and the chemical-shift ratio in eight benign lesions was within 2 standard deviations of the mean chemical-shift ratio in malignant lesions. Six of these eight lesions were misclassified on the basis of both attenuation and chemical-shift-ratio values. CONCLUSION: CT attenuation values are highly correlated with chemical-shift ratios. Both values were indeterminate for a similar subset of benign lesions.
No takes yet. Share an insight, caveat, or question.
Outwater et al. (1996) conducted a cross-sectional in Adrenal masses (n=38). Unenhanced CT vs. Chemical-shift MR imaging was evaluated on Correlation between CT attenuation value and chemical-shift ratio (Correlation 0.85, p=< .000001). Unenhanced CT attenuation values were highly correlated with chemical-shift ratios at MR imaging in evaluating adrenal masses (correlation 0.85, P<0.000001).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: