Key result
The SPREAD technique significantly reduced the standard deviations of estimated IMCL peak areas (p < 10^-8) and reduced Cramer-Rao lower bounds by ~37% compared to spectra before SPREAD.
The SPREAD technique improves the spectral resolution and fitting accuracy of 1H MRSI data for measuring intramyocellular lipids in human calf muscle.
Answers are grounded in this paper and cite their sources.
SPREAD may improve IMCL quantification accuracy in calf MRSI; leaves open clinical or research adoption pending validation.
Proton magnetic resonance spectroscopic imaging ((1) H MRSI) has been used for the in vivo measurement of intramyocellular lipids (IMCLs) in human calf muscle for almost two decades, but the low spectral resolution between extramyocellular lipids (EMCLs) and IMCLs, partially caused by the magnetic field inhomogeneity, has hindered the accuracy of spectral fitting. The purpose of this paper was to enhance the spectral resolution of (1) H MRSI data from human calf muscle using the SPREAD (spectral resolution amelioration by deconvolution) technique and to assess the influence of improved spectral resolution on the accuracy of spectral fitting and on in vivo measurement of IMCLs. We acquired MRI and (1) H MRSI data from calf muscles of three healthy volunteers. We reconstructed spectral lineshapes of the (1) H MRSI data based on field maps and used the lineshapes to deconvolve the measured MRS spectra, thereby eliminating the line broadening caused by field inhomogeneities and improving the spectral resolution of the (1) H MRSI data. We employed Monte Carlo (MC) simulations with 200 noise realizations to measure the variations of spectral fitting parameters and used an F-test to evaluate the significance of the differences of the variations between the spectra before SPREAD and after SPREAD. We also used Cramer-Rao lower bounds (CRLBs) to assess the improvements of spectral fitting after SPREAD. The use of SPREAD enhanced the separation between EMCL and IMCL peaks in (1) H MRSI spectra from human calf muscle. MC simulations and F-tests showed that the use of SPREAD significantly reduced the standard deviations of the estimated IMCL peak areas (p < 10(-8) ), and the CRLBs were strongly reduced (by ~37%).
No takes yet. Share an insight, caveat, or question.
Dong et al. (2014) studied Healthy volunteers (n=3). SPREAD (spectral resolution amelioration by deconvolution) technique vs. Spectra before SPREAD was evaluated on Standard deviations of the estimated IMCL peak areas and Cramer-Rao lower bounds (CRLBs) (CRLBs reduced by ~37%, p=< 10(-8)). The SPREAD technique significantly reduced the standard deviations of estimated IMCL peak areas (p < 10^-8) and reduced Cramer-Rao lower bounds by ~37% compared to spectra before SPREAD.
Synapse has enriched 10 related papers. Consider them for comparative context: