Why the study?
Does high-spatial-resolution MRSI compare favorably with single-voxel MRS for determining lipid content in human skeletal muscle?
Population
Human skeletal muscle
Comparison
High-spatial-resolution spectroscopic imaging… vs Proton single-voxel MR spectroscopy using…
Design
Other
Authors
Loading...
High-resolution MRSI may aid muscle lipid quantification; leaves open standardization and clinical outcome validation.
Does high-spatial-resolution MRSI compare favorably with single-voxel MRS for determining lipid content in human skeletal muscle?
High-resolution MRSI using fat as an internal or external standard is recommended over standard single-voxel MRS for measuring skeletal muscle lipid content to avoid relaxation correction issues.
Weis et al. (2008) studied this question.