Answers are grounded in this paper and cite their sources.
Experimental investigation reveals mechanical and electrical properties in cement mortar with fly ash and PZT, suggesting applications in building materials.
This study experimentally investigated the mechanical properties and electrical resistivity of cement mortar incorporating fly ash and lead zirconate titanate (PZT) for potential application in smart and disaster-resilient building materials. Class F fly ash replaced cement at 0%, 10%, 20%, and 30% by volume. In the PZT mixtures, 5% of the fine-aggregate volume was replaced with PZT powder. Flowability, compressive strength, ultrasonic pulse velocity, water absorption, and electrical resistivity were evaluated at curing ages of 1, 7, 28, and 56 days. Electrical resistivity was measured under saturated surface-dry (SSD) and oven-dried (OD) conditions using direct-current voltages of 50 and 100 V, corresponding to nominal electric-field intensities of 10 and 20 V/cm. At 28 days, compressive strength ranged from 31.0 to 20.4 MPa for the control mixtures and from 29.0 to 19.0 MPa for the PZT mixtures as the fly ash content increased. Under the 50 V SSD condition, the corresponding resistivity ranges were 1870–1588 and 1419–1286 Ω·cm, respectively, whereas under the 100 V OD condition, they were 2671–3013 and 3247–3415 Ω·cm. Increasing the fly ash content improved flowability but generally reduced compressive strength and ultrasonic pulse velocity and increased water absorption because the low-calcium Class F fly ash slowed strength development. The PZT mixtures exhibited slightly lower compressive strength, likely owing to weaker interfacial bonding, but showed distinct electrical behaviour: PZT reduced resistivity under SSD conditions and increased it under OD conditions relative to the control mixtures. Resistivity increased with compressive strength under SSD conditions but decreased with compressive strength under OD conditions because pore water enhanced ionic conduction. Higher applied voltage also reduced the measured resistivity. Overall, moisture condition and measurement voltage strongly governed the electrical response, while the incorporation of 5 vol.% PZT altered the electrical-resistivity characteristics while producing only relatively small differences in the measured basic engineering properties.
No takes yet. Share an insight, caveat, or question.
Chang et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: