Key result
Trans-axillary balloon aortic valvoplasty in infants with severe aortic stenosis significantly reduced the mean instantaneous Doppler gradient from 68 to 37 mmHg (p < 0.0001).
Why the study?
Does balloon aortic valvoplasty via the trans-axillary approach safely reduce aortic valve gradients in young infants with severe aortic valve stenosis?
Observational (n=27)
No
Does balloon aortic valvoplasty via the trans-axillary approach safely reduce aortic valve gradients in young infants with severe aortic valve stenosis?
Trans-axillary balloon aortic valvoplasty is a feasible alternative to the femoral approach in young infants with severe aortic stenosis, effectively reducing gradients with short procedure times, though vascular complications remain a concern.
Answers are grounded in this paper and cite their sources.
Trans-axillary BAV appears feasible in early infancy; leaves open prospective trials versus femoral access.
OBJECTIVES: To assess the feasibility and results of trans-axillary approach for balloon aortic valvoplasty (BAV) in early infancy. BACKGROUND: Severe aortic valve stenosis (SAVS) is rare but serious condition in infancy, which may be promptly treated either by surgical aortic valvotomy or BAV. BAV is usually performed via the femoral artery route, which is associated with significant vascular complications and long procedure times. METHODS: BAV via the trans-axillary approach was performed on twenty-seven sequential infants with SAVS presenting to a single tertiary referral center over an 11-year period. Maximum inflated balloon size was less than or equal to the aortic valve diameter. RESULTS: Twenty-seven infants aged 1-77 days underwent BAV. Weight at time of procedure was 2.0-4.42 kgs. The median procedure and screening times were 82 and 7.9 minutes, respectively. Mean instantaneous Doppler gradient across the aortic valve reduced from 68 +/- 33 to 37 +/- 14 mmHg ( p < 0.0001). Three infants developed at least moderate aortic regurgitation. Right arm pulse volume was decreased in 12 infants; 5 received an intravenous heparin infusion. Longer-term follow-up demonstrated reduced or absent peripheral pulse in 5 infants. Transection of the axillary artery occurred in one infant requiring emergency microvascular repair. There was one post-procedural and one late death due to non-cardiac causes. CONCLUSIONS: In early infancy balloon aortic valvoplasty via the axillary artery approach for severe aortic stenosis is an acceptable and safe alternative to the femoral arterial approach and results in short procedure and screening times. Longer-term vascular follow-up is required.
No takes yet. Share an insight, caveat, or question.
Dua et al. (2006) conducted an observational in Severe aortic valve stenosis (n=27). Trans-axillary approach for balloon aortic valvoplasty was evaluated on Mean instantaneous Doppler gradient across the aortic valve (p=< 0.0001). Trans-axillary balloon aortic valvoplasty in infants with severe aortic stenosis significantly reduced the mean instantaneous Doppler gradient from 68 to 37 mmHg (p < 0.0001).
Synapse has enriched 10 related papers. Consider them for comparative context: