Key result
Venous access with subclavian vein puncture was strongly associated with pneumothorax requiring a chest tube.
Why the study?
What are the risk factors for pneumothorax treated with a chest tube following cardiac pacing device implantation?
Cohort (n=28,860)
Yes
What are the risk factors for pneumothorax treated with a chest tube following cardiac pacing device implantation?
Subclavian vein puncture is a major risk factor for pneumothorax during pacemaker implantation, suggesting cephalic vein cut-down should be preferred to minimize this complication.
Answers are grounded in this paper and cite their sources.
Alerts clinicians to higher pneumothorax risk in women and octogenarians; leaves open optimal prevention strategies pending interventional trials.
AIM: To identify risk factors for pneumothorax treated with a chest tube after cardiac pacing device implantation in a population-based cohort. METHODS AND RESULTS: A nationwide cohort study was performed based on data on 28 860 patients from the Danish Pacemaker Register, which included all Danish patients who received their first pacemaker (PM) or cardiac resynchronization device from 1997 to 2008. Multiple logistic regression was used to estimate adjusted odds ratios (aOR) with 95% confidence intervals for the association between risk factors and pneumothorax treated with a chest tube. The median age was 77 years (25th and 75th percentile: 69-84) and 55% were male (n = 15 785). A total of 190 patients (0.66%) were treated for pneumothorax, which was more often in women [aOR 1.9 (1.4-2.6)], and in patients with age >80 years [aOR 1.4 (1.0-1.9)], a prior history of chronic obstructive pulmonary disease [aOR 3.9 (1.6-9.5)], implantation of a dual-chamber PM [aOR 1.5 (1.0-2.2)], venous access with subclavian vein puncture [aOR 7.8 (4.9-12.5)], venous access with both subclavian vein puncture and cephalic vein cut-down [aOR 5.7 (3.0-10.8)], and implantation in a non-university centre [aOR 2.1 (1.6-2.9)]. CONCLUSION: Pneumothorax treated with a chest tube remains a clinically important problem in device therapy. The cephalic vein cut-down technique should be applied whenever possible to avoid this complication.
No takes yet. Share an insight, caveat, or question.
Kirkfeldt et al. (2012) conducted a cohort in Cardiac pacing device implantation (n=28,860). Venous access with subclavian vein puncture vs. Other venous access techniques was evaluated on Pneumothorax treated with a chest tube (OR 7.8, 95% CI 4.9-12.5). Venous access with subclavian vein puncture was strongly associated with pneumothorax requiring a chest tube.
Synapse has enriched 10 related papers. Consider them for comparative context: