Key result
High-sensitive troponin T improved early diagnostic accuracy for acute myocardial infarction compared with conventional troponins, achieving 99% sensitivity and 83% specificity at two hours.
Why the study?
Does high-sensitive troponin T improve early diagnostic accuracy for acute myocardial infarction compared to conventional troponins in chest pain patients without ST-elevations?
Observational (n=233)
Does high-sensitive troponin T improve early diagnostic accuracy for acute myocardial infarction compared to conventional troponins in chest pain patients without ST-elevations?
Answers are grounded in this paper and cite their sources.
High-sensitive troponin T improves early diagnostic accuracy for acute myocardial infarction compared to conventional assays, allowing for rapid rule-out within the first few hours of admission.
OBJECTIVES: The aim of this study was to compare the early diagnostic value of the Roche high-sensitive troponin T (Hs-TnT) and that of conventional troponins. DESIGN: A total of 233 consecutive chest pain patients without ST-elevations were included. Hs-TnT was compared with two conventional assays (Roche troponin T [fourth generation] and Beckman Coulter Accu-TnI) on admission and at two hours. RESULTS: When acute Myocardial Infarction (MI) was defined by conventional troponins and prespecified decision limits (Hs-TnT ≥ 14 ng/l, conventional TnT ≥ 0.04 μg/l, and Accu-TnI ≥ 0.06 μg/l) were used, Hs-TnT had a higher sensitivity but a lower specificity than conventional troponins both on admission and after two hours. When the biomarkers were compared in a ROC analysis there were no significant differences with regard to AUC. When acute MI was defined by Hs-TnT, the diagnostic performance of Hs-TnT remained very high (on admission: sensitivity 96%, specificity 85%, at two hours: sensitivity 99%, specificity 83%) whereas that of conventional troponins became lower, mainly because of lower sensitivity. CONCLUSION: In conclusion, when acute MI is defined by a high sensitive troponin assay, the use of Hs-TnT improves the early diagnostic accuracy compared with conventional troponins. By measuring Hs-TnT it seems possible to exclude acute MI already within the first few hours from admission.
No takes yet. Share an insight, caveat, or question.
Melki et al. (2011) conducted an observational in Chest pain without ST-elevations (n=233). Roche high-sensitive troponin T (Hs-TnT) vs. Conventional troponins (Roche troponin T fourth generation and Beckman Coulter Accu-TnI) was evaluated on Early diagnostic value for acute Myocardial Infarction (MI). High-sensitive troponin T improved early diagnostic accuracy for acute myocardial infarction compared with conventional troponins, achieving 99% sensitivity and 83% specificity at two hours.