Key result
High-sensitivity cardiac troponin T >0.014 μg/L independently predicted death (HR 2.60; 95% CI 1.42-4.74) and improved risk reclassification compared to standard troponin T.
Why the study?
Does high-sensitivity cardiac troponin T improve risk prediction for death compared to standard cardiac troponin T in patients presenting with acute chest pain?
Cohort (n=1,159)
Does high-sensitivity cardiac troponin T improve risk prediction for death compared to standard cardiac troponin T in patients presenting with acute chest pain?
High-sensitivity cardiac troponin T significantly improves the prediction of death at 24 months compared to standard troponin T in unselected patients presenting with acute chest pain.
Answers are grounded in this paper and cite their sources.
May improve death risk stratification in acute chest pain; hypothesis-generating, requires prospective validation before practice change.
BACKGROUND: High-sensitivity cardiac troponin assays have better analytical precision and sensitivity than earlier-generation assays when measuring cardiac troponin at low concentrations. We evaluated whether use of a high-sensitivity assay could further improve risk stratification compared with a standard cardiac troponin assay. METHODS: We enrolled consecutive patients presenting with acute chest pain, 30% of whom were diagnosed with acute coronary syndrome. Blood samples were drawn at the time of presentation. We measured cardiac troponin T with a standard fourth-generation assay (cTnT) and a high-sensitivity assay (hs-cTnT) (both Roche Diagnostics) and followed the patients for 24 months. RESULTS: Of the 1159 patients, 76 died and 42 developed an acute myocardial infarction (AMI). Prognostic accuracy of hs-cTnT for death was significantly higher [area under ROC curve (AUC) 0.79, 95% CI 0.74-0.84] than that of cTnT (AUC 0.69, 95% CI 0.62-0.76; P < 0.001). After adjustment for Thrombolysis in Myocardial Infarction (TIMI) risk score (that included the cTnT assay result), hs-cTnT above the 99th percentile (0.014 μg/L) was associated with a hazard ratio for death of 2.60 (95% CI 1.42-4.74). Addition of hs-cTnT to the risk score improved the reclassification of patients (net reclassification improvement 0.91; 95% CI 0.67-1.14; P < 0.001). Subgroup analyses showed that this effect resulted from the better classification of patients without AMI at time of testing. hs-cTnT outperformed cTnT in the prediction of AMI during follow-up (P=0.02), but was not independently predictive for this endpoint. CONCLUSIONS: Concentrations of hs-cTnT >0.014 μg/L improve the prediction of death but not subsequent AMI in unselected patients presenting with acute chest pain.
No takes yet. Share an insight, caveat, or question.
Hochholzer et al. (2011) conducted a cohort in acute chest pain (n=1,159). High-sensitivity cardiac troponin T (hs-cTnT) vs. Standard fourth-generation cardiac troponin T (cTnT) was evaluated on death (HR 2.60, 95% CI 1.42-4.74, p=<0.001). High-sensitivity cardiac troponin T >0.014 μg/L independently predicted death (HR 2.60; 95% CI 1.42-4.74) and improved risk reclassification compared to standard troponin T.