Key result
3-dimensional color Doppler echocardiography (3D-PISA) yielded significantly higher mitral regurgitation volumes than 2D-PISA (59.5 vs 52.4 mL; P=0.005), which often underestimated MR severity.
Why the study?
Does 3D-color Doppler echocardiography provide more accurate quantification of mitral regurgitation compared to 2D-color Doppler echocardiography in patients with MR?
Observational (n=221)
Does 3D-color Doppler echocardiography provide more accurate quantification of mitral regurgitation compared to 2D-color Doppler echocardiography in patients with MR?
3D-PISA is more accurate than 2D-PISA for quantifying mitral regurgitation, particularly in cases with severe, eccentric MR or asymmetrical orifices, where 2D-PISA significantly underestimates severity.
3D color Doppler is feasible for MR quantification in most patients; leaves open accuracy validation before clinical use.
BACKGROUND: The aim of this study is to explore the differential effect of 3-dimensional color Doppler echocardiography for the quantification of mitral regurgitation (MR). Two-dimensional color Doppler echocardiography-based MR quantification has well-documented limitations. METHODS AND RESULTS: We consecutively enrolled 221 patients with MR. Adequate image quality was obtained by 2D- and 3D-color Doppler echocardiography in 211 (95.5%) patients. The quantitative differences between the MR volumes obtained by 2D- and 3D-proximal isovelocity surface area (PISA) were analyzed in various MR subgroups. In the validation cohort (n=52), MR volume obtained by 3D-PISA showed a better agreement with phase-contrast cardiac MRI than 2D-PISA (r=0.97 versus 0.84). In all 211 patients, 2D-PISA underestimated the MR volume when compared with 3D-PISA (52.4±19.6 versus 59.5±25.6 mL; P=0.005). A total of 33.3% with severe MR based on 3D-PISA were incorrectly assessed by 2D-PISA as having nonsevere MR. In the subgroup analysis, the MR severity (odds ratio, 6.96; 95% confidence interval, 3.04-15.94; P<0.001) and having an asymmetrical orifice (odds ratio, 11.48; 95% confidence interval, 3.72-35.4; P<0.001), and an eccentric jet (odds ratio, 3.82; 95% confidence interval, 1.27-11.48; P=0.017) were predictors of significant difference in MR volume (>15 mL) between 2D- and 3D-PISA methods. CONCLUSIONS: Quantification of MR by 3D-PISA method is clinically feasible and more accurate than the current 2D-PISA method. MR quantification by 2D-PISA significantly underestimated MR volume with severe, eccentric MR with an asymmetrical orifice. This article demonstrates that 3D-color Doppler echocardiography could be used as a valuable tool to confirm treatment strategy in patients with significant MR.
No takes yet. Share an insight, caveat, or question.
Choi et al. (2014) conducted an observational in Mitral regurgitation (n=221). 3-dimensional color Doppler echocardiography (3D-PISA) vs. 2-dimensional color Doppler echocardiography (2D-PISA) was evaluated on Mitral regurgitation volume (p=0.005). 3-dimensional color Doppler echocardiography (3D-PISA) yielded significantly higher mitral regurgitation volumes than 2D-PISA (59.5 vs 52.4 mL; P=0.005), which often underestimated MR severity.