Why the study?
Does automated 3D PISA and stroke volume technique accurately quantify mitral regurgitation compared to cardiac magnetic resonance imaging in patients with functional MR?
Population
In vitro model of mitral regurgitation and 30 patients with functional mitral regurgitation
Comparison
Automated 3-dimensional proximal isovelocity… vs 2-dimensional PISA, flowmeter, and cardiac…
Design
Cross-sectional
Authors
Loading...
Supports integrated 3D PISA for functional MR quantification; hypothesis-generating and requires prospective outcome validation before practice change.
Does automated 3D PISA and stroke volume technique accurately quantify mitral regurgitation compared to cardiac magnetic resonance imaging in patients with functional MR?
Automated real-time 3D volume color flow Doppler-based integrated PISA provides a more accurate quantification of functional mitral regurgitation than 2D PISA, with results comparable to cardiac magnetic resonance imaging.
Thavendiranathan et al. (2012) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: