Key result
Atrial fibrillation in patients with a dual-chamber pacemaker was associated with a significant increase in LA volume index and E/é, and a decrease in SV index and ejection fraction.
Why the study?
Pacemaker-detected atrial high-rate episodes (AHREs) may identify patients at increased risk for death, motivating an investigation into the echocardiographic and clinical parameters associated with AHREs in patients with a dual-chamber pacemaker.
Are specific echocardiographic and clinical parameters associated with the occurrence of atrial high-rate episodes in patients with dual-chamber pacemakers?
Observational (n=208)
No
Are specific echocardiographic and clinical parameters associated with the occurrence of atrial high-rate episodes in patients with dual-chamber pacemakers?
Answers are grounded in this paper and cite their sources.
Echocardiographic parameters including increased LA volume index and E/é, and decreased SV index and EF, are significantly associated with the development of atrial high-rate episodes in patients with dual-chamber pacemakers.
Background: Atrial fibrillation (AF) is the commonest sustained disorder of cardiac rhythm. Permanent pacemaker (PPM)-detected atrial high-rate episodes (AHREs) of even 5-minute duration may identify patients at increased risk for death. Objective: This study aimed to investigate the association of echocardiographic and clinical parameter with the occurrence of AHREs in patients with a dual-chamber pacemaker. Patients and methods: this retrospective study included 208 patients. It was conducted in the Cardiology Department, Faculty of Medicine, Zagazig University Hospitals. The patients were classified according to development of AF into 2 groups: Group (A) involved 77 patients with AF and group < strong> (B) involved 131 patients without AF. Results: The mean age of the studied cases was 61.67 ± 8.13 years and 53.4% were females. Mean SBP was 122.6 ± 16.8 mmHg while mean DBS was 76.9 ± 10.14 mmHg. There was a high statistically significant increase in LA volume index, E/é and a high statistically significant decrease in SV index and EF among AF group compared to non AF group < strong>. Conclusion: In our opinions patients with CIED detected AHREs need oral anticoagulation to prevent thromboembolic events and decrease burden of ischemic stroke.
No takes yet. Share an insight, caveat, or question.
Mahmoud et al. (2022) conducted an observational in Atrial fibrillation in patients with a dual-chamber pacemaker (n=208). Atrial fibrillation vs. No atrial fibrillation was evaluated on Echocardiographic and clinical parameters (LA volume index, E/é, SV index, EF). Atrial fibrillation in patients with a dual-chamber pacemaker was associated with a significant increase in LA volume index and E/é, and a decrease in SV index and ejection fraction.
Synapse has enriched 10 related papers. Consider them for comparative context: