Key result
Acute RyR2 activation with the Epac activator 8-CPT reversibly induced ventricular tachycardia in specific association with reduced conduction velocity in murine hearts.
Why the study?
Does Epac-mediated RyR2 activation induce ventricular tachycardia and reduce conduction velocity in murine hearts?
Does Epac-mediated RyR2 activation induce ventricular tachycardia and reduce conduction velocity in murine hearts?
Acute RyR2 activation by Epac reversibly induces ventricular tachycardia associated with reduced conduction velocity in murine hearts.
Answers are grounded in this paper and cite their sources.
Indicates Epac-RyR2 pathway in murine VT; hypothesis-generating for human arrhythmogenesis and targets.
Recent papers have attributed arrhythmic substrate in murine RyR2-P2328S hearts to reduced action potential (AP) conduction velocities (CV), reflecting acute functional inhibition and/or reduced expression of sodium channels. We explored for acute effects of direct exchange protein directly activated by cAMP (Epac)-mediated ryanodine receptor-2 (RyR2) activation on arrhythmic substrate and CV. Monophasic action potential (MAP) recordings demonstrated that initial steady (8 Hz) extrinsic pacing elicited ventricular tachycardia (VT) in 0 of 18 Langendorff-perfused wild-type mouse ventricles before pharmacological intervention. The Epac activator 8-CPT (8-(4-chlorophenylthio)-2'-O-methyladenosine-3',5'-cyclic monophosphate) (VT in 1 of 7 hearts), and the RyR2 blocker dantrolene, either alone (0 of 11) or with 8-CPT (0 of 9) did not then increase VT incidence (P>.05). Both progressively increased pacing rates and programmed extrasystolic (S2) stimuli similarly produced no VT in untreated hearts (n=20 and n=9 respectively). 8-CPT challenge then increased VT incidences (5 of 7 and 4 of 8 hearts respectively; P<.05). However, dantrolene, whether alone (0 of 10 and 1 of 13) or combined with 8-CPT (0 of 10 and 0 of 13) did not increase VT incidence relative to those observed in untreated hearts (P>.05). 8-CPT but not dantrolene, whether alone or combined with 8-CPT, correspondingly increased AP latencies (1.14±0.04 (n=7), 1.04±0.03 (n=10), 1.09±0.05 (n=8) relative to respective control values). In contrast, AP durations, conditions for 2:1 conduction block and ventricular effective refractory periods remained unchanged throughout. We thus demonstrate for the first time that acute RyR2 activation reversibly induces VT in specific association with reduced CV.
No takes yet. Share an insight, caveat, or question.
Li et al. (2017) studied Arrhythmic substrate / Ventricular tachycardia. Epac activator 8-CPT vs. Untreated hearts was evaluated on Ventricular tachycardia incidence (p=<.05). Acute RyR2 activation with the Epac activator 8-CPT reversibly induced ventricular tachycardia in specific association with reduced conduction velocity in murine hearts.