Key result
Laser-induced fluorescence spectroscopy identified scarred endocardium in human necropsy specimens with 100% sensitivity and 70% specificity.
Why the study?
Can laser-induced fluorescence emission spectroscopy differentiate normal from fibrotic endocardium and myocardium in vitro?
Can laser-induced fluorescence emission spectroscopy differentiate normal from fibrotic endocardium and myocardium in vitro?
Fluorescence emission spectroscopy can accurately differentiate normal from fibrotic myocardial tissue in vitro, suggesting potential utility for guiding laser ablation of arrhythmogenic scars.
Answers are grounded in this paper and cite their sources.
Laser-induced fluorescence spectra distinguished fibrotic endocardium in necropsy samples; leaves open in vivo diagnostic utility for ablation guidance.
UNLABELLED: Laser-induced fluorescence has been developed as a guidance system for laser angioplasty. Laser ablation has been used for resection of arrhythmogenic ventricular scar. We have investigated the use of laser-induced fluorescence for the detection of fibrotic and ischemic changes in endocardium and myocardium. Fluorescence emission spectra from human necropsy specimens were correlated with histologic examination. Normalized fluorescence intensity detected from both the endocardial and the myocardial surfaces of the fibrotic ventricular specimens was significantly higher than that of corresponding normal specimens at 440 to 475 nm. Fibrotic endocardium could be identified by a fluorescence emission intensity ratio less than 1.5 for wavelength ratio 375/450nm. Acutely infarcted endocardium was recognizable by a ratio of 1.5 to 2.0. The specificity and sensitivity of detection of scarred endocardium was 70 and 100%, respectively. Fibrotic myocardium was also consistently identified by fluorescence spectroscopy. CONCLUSION: Fluorescence emission spectroscopy can differentiate normal and fibrotic endocardium and myocardium, in vitro. This technique may be useful for guidance during laser ablation of arrhythmogenic ventricular scar.
No takes yet. Share an insight, caveat, or question.
Perk et al. (1991) studied Fibrotic and ischemic changes in endocardium and myocardium. Laser-induced fluorescence spectroscopy vs. Normal specimens was evaluated on Detection of scarred endocardium (100% sensitivity, 70% specificity). Laser-induced fluorescence spectroscopy identified scarred endocardium in human necropsy specimens with 100% sensitivity and 70% specificity.
Synapse has enriched 10 related papers. Consider them for comparative context: