Key result
Compliant aortic phantoms reveal atherogenic flow recirculation zones missed by rigid models.
Why the study?
Most studies overlook arterial compliance and pulsatile flow, yet rigid wall assumptions can lead to overestimation of wall shear stress.
Hemodynamic studies of the aorta should incorporate arterial compliance, as rigid models fail to predict important flow recirculation zones associated with atherosclerosis development.
Answers are grounded in this paper and cite their sources.
Compliant phantoms detect atherosclerosis-prone recirculation missed by rigid models; leaves open whether compliance is required in all aortic hemodynamic studies.
The aorta is a high risk region for cardiovascular disease (CVD). Haemodynamic patterns leading to CVD are not well established despite numerous experimental and numerical studies. Most overlook effects of arterial compliance and pulsatile flow. However, rigid wall assumptions can lead to overestimation of wall shear stress; a key CVD determinant. This work investigates the effect of compliance on aortic arch haemodynamics experiencing pulsatility. Rigid and compliant phantoms of the arch and brachiocephalic branch (BCA) were manufactured. Stereoscopic particle image velocimetry was used to observe velocity fields. Higher velocity magnitude was observed in the rigid BCA during acceleration. However, during deceleration, the compliant phantom experienced higher velocity. During deceleration, a low velocity region initiated and increased in size in the BCA of both phantoms with irregular shape in the compliant. At mid-deceleration, considerably larger recirculation was observed under compliance compared to rigid. Another recirculation region formed and increased in size on the inner wall of the arch in the compliant during late deceleration, but not rigid. The recirculation regions witnessed identify as high risk areas for atherosclerosis formation by a previous ex-vivo study. The results demonstrate necessity of compliance and pulsatility in haemodynamic studies to obtain highly relevant clinical outcomes.
No takes yet. Share an insight, caveat, or question.
Yazdi et al. (2021) studied this question. Compliant aortic arch phantom vs. Rigid aortic arch phantom was evaluated on Velocity fields and flow recirculation. Compliant ascending aorta phantoms demonstrated clinically important flow recirculation zones in areas at high risk for atherosclerosis that were not observed in rigid phantoms.