Key result
In a compliant model of a diseased artery, wall compliance increased instantaneous velocities and broadened velocity spectra, with the greatest strain magnitude occurring at the neck of the bulge.
Answers are grounded in this paper and cite their sources.
This experimental fluid dynamics study demonstrates that arterial wall compliance in malformations increases flow complexity and localizes the highest strain at the bulge neck, highlighting the mechanical basis for rupture susceptibility.
Walls of an artery undergo periodic deformation when subjected to time-dependent pressure and wall shear stress. A pathological malformation will appear in the arterial wall that further increases the complexity of the flow field. The present study examines flow patterns in a compliant model resembling the diseased portion of an artery subjected to oscillatory flow (Re ∼ 500–800 and Wo ∼ 10–12). A particle tracking technique using two orthogonally placed cameras is employed for obtaining the position and three components of velocity of a density matched particle. The effect of fluid loading on the compliant wall is investigated by tracking its boundary in time. Results obtained in the present work reveal that wall compliance increases the instantaneous velocities and broadens the velocity spectra, while a persistent signature of wall movement is visible in the phase-averaged fluid velocity components. These differences increase with Reynolds number as well as the oscillation frequency. Wall movement shows a greater level of periodicity at the forcing frequency of oscillatory flow but with a slightly positive Lyapunov exponent. The largest Lyapunov exponent of the axial velocity component is small and positive while those of the secondary flow in the transverse plane are much greater and positive, indicative of chaotic flow. These exponents increase further with wall compliance. Positions on the wall that fall close to the neck of the bulge show the greatest strain magnitude. Consequently, such locations are most susceptible to rupture.
No takes yet. Share an insight, caveat, or question.
Usmani et al. (2016) studied Arterial malformation. Oscillatory flow in a compliant model was evaluated on Flow patterns, instantaneous velocities, and Lyapunov exponents. In a compliant model of a diseased artery, wall compliance increased instantaneous velocities and broadened velocity spectra, with the greatest strain magnitude occurring at the neck of the bulge.
Synapse has enriched 10 related papers. Consider them for comparative context: