Key result
First-generation cryoballoons showed comparable overall recurrence rates to second-generation cryoballoons in patients with atrial fibrillation (62.4% vs 74.2%, p=0.13).
Why the study?
Although both first- and second-generation cryoballoons are efficient and safe for AF, the superiority of CB2 over CB1 remained controversial, particularly regarding long-term outcomes in a Chinese population.
Does 2nd-generation cryoballoon ablation improve recurrence rates or safety compared to 1st-generation cryoballoon in patients with atrial fibrillation?
Cohort (n=278)
Does 2nd-generation cryoballoon ablation improve recurrence rates or safety compared to 1st-generation cryoballoon in patients with atrial fibrillation?
First- and second-generation cryoballoons demonstrate comparable long-term efficacy and safety for pulmonary vein isolation in patients with atrial fibrillation.
This observational comparison should not alter cryoballoon selection; leaves open need for randomized trials in AF.
objective: Both first and second generation cryoballoons (CB1 and CB2) are efficient and safe treatments for patients with atrial fibrillation (AF). However, the superiority of CB2 over CB1 remains controversial. Our purpose was to compare ablation outcomes and complications between two generation CB especially in the long-term follow-up and in Chinese population. Methods: 278 consecutive patients underwent CB ablation were included, with 139 cases of 1st and 2nd generation CB respectively. Patients profiles, periprocedural details and clinical events were recorded and compared between two cohorts. Results: Baseline characteristics were similar. 1st generation CB group showed more overall times of freeze per vein (1.8±1.0 vs 1.6±0.8, p<0.01) and longer time-to-isolation in left superior pulmonary vein (91.0 ±49.1s vs 54.1±32.4 p=0.01). After three-years follow-up, the procedure complications had no difference between two groups. Through a mean follow-up period of 19.00±10.66 months, overall recurrence was comparable(62.4% vs 74.2%, p=0.13)and the survival analysis shows no difference either (Logrank P = 0.1807). The complications during follow-up showed no differences, including stroke events [3/133 vs 1/128, p=0.62], major hemorrhagic events [3/133 vs 1/128, p=0.62] and death of any cause [5/133 vs 2/128, p=0.25]. Conclusions: 1st and 2nd generation CBs are equally efficient and safe for PV ablation procedure and they are both suitable for Chinese population
No takes yet. Share an insight, caveat, or question.
Zheng et al. (2020) conducted a cohort in Atrial fibrillation (n=278). 1st-generation cryoballoon (CB1) vs. 2nd-generation cryoballoon (CB2) was evaluated on Overall recurrence (p=0.13). First-generation cryoballoons showed comparable overall recurrence rates to second-generation cryoballoons in patients with atrial fibrillation (62.4% vs 74.2%, p=0.13).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: