Answers are grounded in this paper and cite their sources.
This work studies a polypropylene/ammonium polyphosphate/polyurethane intumescent fire retardant material. It reports the foaming expansion under a normal strain and the variation of the apparent viscosity of the heat-treated material measured using a plate–plate rheometer. The loss of the protective character of the intumescent coating is discussed. It is proposed that it is related to a limited foaming expansion value, an increase of its apparent initial viscosity and a decrease of this viscosity with time when a normal force and a sinusoidal strain are both applied. The changes in the dynamic properties of the system are explained by the chemistry of the intumescence process.
No takes yet. Share an insight, caveat, or question.
Bugajny et al. (1999) studied this question.