Key result
Physics-based mathematical modeling and finite element simulations integrate complex cardiovascular variables to quantify regional heart wall stress and support medical device evaluation.
Answers are grounded in this paper and cite their sources.
This editorial highlights the potential of physics-based mathematical modeling and finite element simulations to bridge basic cardiovascular physiology and clinical practice, including quantifying myocardial wall stress and conducting virtual clinical trials for medical device evaluation.
Biomedical research has enjoyed an eruption of reductionism where organs are reduced to their respective tissues, cells and molecules. Although reductionism (including proteomic and genomic) is a powerful approach to provide information on the components of the system, integration of the components and their interactions are ultimately necessary to reveal organ phenotype and function1-2. Biological integration is inherently complex and requires mathematical “gluing” of numerous components of the system with many variables. Physics-based mathematical modeling is well tailored for the task when the number of variables is so great that it eludes intuition. The past several decades have enjoyed enormous advancements in mathematical modeling as computational capabilities have advanced substantially and experimental databases to inform and calibrate the computational models have become available to reduce ad hoc assumptions. Applications of mathematical models have ranged from understanding basic biological systems to generate new hypotheses to patient-specific computational models that can aid medical diagnosis and help design optimal treatments3. Currently, most computational biomechanics modeling, however, is still in the research and development stage. Furthermore, the utility of mathematical models remains largely removed from the clinic. The objective of this issue of “Frontiers in Physiology” is to place the spotlight on integration with emphasis on clinical translation of mathematical models. Here, we focus on the cardiovascular system which includes the heart and blood vessels as this discipline has been at the frontier of computational modeling both for understanding physiology and pathophysiology. For example, it is now clinical practice to compute pressure drop in the coronary arteries using computerized tomography (to determine fractional flow reserve)4, and non-invasively measure regional heart wall motion and strain in patients by using echocardiography or cardiac magnetic resonance imaging, in order to diagnose localized contractile disorders. On the latter, there still is no reliable way to directly measure the forces or stresses that produce abnormal heart wall motion. Cardiologists have long been interested in quantification of heart wall stress because it is a primary determinant of coronary blood flow and myocardial oxygen consumption5. Moreover, changes in wall stress are believed to be stimuli to cardiac growth and remodeling6. Since regional heart wall stress cannot be measured reliably, mathematical modeling based on the conservation laws of continuum mechanics is needed. Because heart wall geometry (including its fibrous architecture) is fully 3D and the mechanical properties of beating myocardium are nonlinear, there are no exact solutions of the governing differential equations of motion. Thus, numerical methods are required to find numerical approximations. The most versatile numerical method for simulation of cardiovascular system is the finite element (FE) method7, which is widely used in the automotive and aerospace industries. Most FE models concerned with heart disease include only the left ventricular (LV) heart chamber because it is under the greatest stress (highest pressures) and thus, most prone to failure.Currently, numerous computational models can simulate the behavior of the LV, a few models can simulate both ventricles, and even fewer can simulate all full four-chambered heart8. The response of FE model is governed by realistic electrical, structural, and fluid flow physics. Significant recent improvements have been made in determination of diastolic9 and systolic10 myocardial material properties in FE models of normal human LV11. Relatively few computational studies have investigated the effects of mechanical circulatory support devices on cardiac function using realistic geometries12-13. A recent study of the effects of an LV assist device on acute left heart failure10 presented stress results in both ventricles. Medical devices play a critical role in the lives of millions of people worldwide. A recent review in the New England Journal of Medicine14 focused on the strategy used by the U.S. Food and Drug Administration (FDA) and made special tribute to the ways in which the evaluation of devices is distinct from that of drugs. The article focused on two examples that illustrate ways in which the FDA has allowed flexibility in gathering clinical data to support device approval. One example was the use of modeling and engineering tests to reduce clinical trial requirements. It concerned the Medtronic Revo MRI pacemaker system, which was approved in 2011 as the first pacemaker indicated to allow patients implanted with the device to undergo MRI. FDA approval rested primarily on robust mathematical modeling that was validated with bench and animal studies. The modeling data, which simulated thousands of combinations of device and patient geometries and MRI scan conditions, provided strong evidence that even worst-case conditions would be very unlikely to result in detrimental lead heating. As expected from the modeling results, the clinical trial showed no evidence of clinically relevant MRI-induced lead heating, as assessed by changes in the pacing capture threshold. This approach of gathering a modest clinical data set to confirm robust bench and modeling data has been used to support number of subsequent approvals for MRI compatible pacemakers and implantable cardioverter-defibrillators. It is likely that extensive premarket approval studies for next-generation devices may not be necessary as utility of computational simulations to support FDA submissions is fully realized. In the future, computer-based modeling may allow for much smaller clinical trials or may change the way medical industry thinks about running trials, in that some ‘clinical’ information may be derived from simulations; i.e., “virtual clinical trials”. It is our hope that this edition of “Frontiers in Physiology” titled “Mathematical Modeling of Cardiovascular Systems: From Physiology to the Clinic“ will serve to bring powerful analytical tools to the clinic that improve safety and efficacy of existing treatments and advance novel diagnostics and therapeutics to the clinic. In this spirit, we are delighted to include 23 articles contributed by 101 authors to this special issue. The topics range from medical devices, to models of cardiac and vascular system in health and disease from molecular to the organ system. To promote these and other translational and transformational efforts, it is important to encourage further computational modeling that range from molecular, to cellular, to tissues and organs in partnership with experimental validation. Validation is key to this effort as it will boost confidence in the computational simulations.
No takes yet. Share an insight, caveat, or question.
Kassab et al. (2019) conducted an editorial in Cardiovascular disease and physiology. Physics-based mathematical and computational modeling (e.g., finite element method) was evaluated. Physics-based mathematical modeling and finite element simulations integrate complex cardiovascular variables to quantify regional heart wall stress and support medical device evaluation.
Synapse has enriched 10 related papers. Consider them for comparative context: