Key result
Biventricular pacing decreased QT dispersion and T(peak-end) interval compared to baseline sinus rhythm in heart failure patients.
Why the study?
Does biventricular pacing improve ECG markers of ventricular repolarization in patients with congestive heart failure and LBBB compared to sinus rhythm or single-ventricle pacing?
Does biventricular pacing improve ECG markers of ventricular repolarization in patients with congestive heart failure and LBBB compared to sinus rhythm or single-ventricle pacing?
Biventricular pacing significantly reduces ECG markers of ventricular dispersion of repolarization compared to baseline sinus rhythm or single-ventricle pacing in heart failure patients with LBBB.
Answers are grounded in this paper and cite their sources.
Biventricular pacing was associated with reduced repolarization dispersion in HF with LBBB; hypothesis-generating and requires randomized confirmation before practice change.
INTRODUCTION: Biventricular pacing has been shown to improve the clinical status of patients with congestive heart failure, but little is known about its influence on ventricular repolarization. The aim of our study was to evaluate the effect of biventricular pacing on ECG markers of ventricular repolarization in patients with congestive heart failure. METHODS AND RESULTS: Twenty-five patients with congestive heart failure, sinus rhythm (SR), and complete LBBB (6 females; age 61 +/- 8 years; NYHA class II-III; echocardiographic ejection fraction 21 +/- 5%; QRS > or = 130 ms) underwent permanent biventricular DDDR pacemaker implantation. A high-resolution 65-lead body-surface ECG recording was performed at baseline and during right-, left-, and biventricular pacing, and the total 65-lead root mean square curve of the QRST complex and the interlead QT dispersion were assessed. The QRS duration was increased during right (RV)- and left ventricular (LV) pacing (127 +/- 26% and 117 +/- 40%; P < 0.05), as compared to SR (100%) and biventricular pacing (93 +/- 16%; ns). The QTc interval was increased during RV and LV pacing (112 +/- 12% and 114 +/- 14%; P < 0.05) as compared to SR (100%) or biventricular pacing (99 +/- 12%). There was no effect on JT interval during all pacing modes. The T(peak-end) interval was increased during right (120 +/- 34%; P < 0.01) and LV pacing (113 +/- 29%; P < 0.05) but decreased during biventricular pacing (81 +/- 19%; P < 0.01). A similar effect was found for the T(peak-end) integral and the T(peak) amplitude. QT dispersion was increased during right ventricular (129 +/- 16 ms; P < 0.05) and decreased during biventricular pacing (90 +/- 12 ms; P < 0.01), as compared to SR (114 +/- 22 ms). CONCLUSIONS: Using a high-resolution surface ECG, biventricular pacing resulted in a significant reduction of ECG markers of ventricular dispersion of repolarization.
No takes yet. Share an insight, caveat, or question.
Berger et al. (2005) studied Congestive heart failure (n=25). Biventricular pacing vs. Sinus rhythm (baseline) and single-ventricle pacing was evaluated on QT dispersion (p=<0.01). Biventricular pacing decreased QT dispersion and T(peak-end) interval compared to baseline sinus rhythm in heart failure patients.
Synapse has enriched 10 related papers. Consider them for comparative context: