Answers are grounded in this paper and cite their sources.
The design of synchronous torque couplers based upon the utilization of high coercive force rare-earth cobalt permanent magnets is considered. For such units, it is generally required to obtain a given torque output with a minimum volume of magnetic material, subject to whatever design constraints may exist. The maximum torque for such optimized configurations is shown to be5.6 × 10⁻³ (Bᵣ²r̄/Δ)and10⁻²Bᵣ²per unit volume of magnetic material and inner coupler element, respectively, wherer̄is the average radius in the gap of widthΔ, r̄/Δ 1, and Bris the remanent flux density. Examples of such optimal designs are given and possible alternate design criteria are briefly discussed.
No takes yet. Share an insight, caveat, or question.
Hornreich et al. (1978) studied this question.