A novel PRN-coded Doppler radar with Delta-Sigma modulation can accurately measure human vital signs in noisy environments by isolating Doppler frequencies.
Answers are grounded in this paper and cite their sources.
May enable non-contact vital sign monitoring in clutter; leaves open clinical validation before practice adoption.
A distance selective pseudo‐random noise (PRN)‐coded Doppler radar is proposed. The radar is capable of measuring the vital signs of a human in a noisy environment with high precision. The distance selectivity feature is achieved by the use of PRN modulation to focus on the desired target at a certain distance and suppress the Doppler frequencies of other targets at different distances. In addition, an offset signal using Delta–Sigma modulation is generated to cope with the suppression of low‐Doppler frequencies, very close to DC, in AC‐coupled systems. The authors compare the performance of the proposed radar system to a frequency modulated continuous wave radar in measuring the Doppler frequencies of two loudspeakers located at different ranges. In addition, they experimentally evaluated the proposed radar in measuring the vital signs of a human in a noisy environment. The radar is capable of isolating the Doppler frequencies of the vital signs from the surrounding noise. In addition, vital signs information is preserved at higher frequencies away from the high‐pass filter in AC‐coupled systems.
No takes yet. Share an insight, caveat, or question.
Abouzaid et al. (2020) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: