Quantitative assessment of myocardial perfusion using CMR correlates well with known myocardial blood flow in an isolated porcine heart model.
CMR perfusion quantification shows strong agreement in isolated porcine hearts; leaves open translation to clinical human use.
To validate quantitative myocardial perfusion CMR against known myocardial blood flow rates in the isolated perfused porcine heart. Perfusion imaging visualizes early changes within the ischaemic cascade and has been shown to accurately detect significant coronary artery stenoses. First pass myocardial perfusion CMR yields high spatial resolution and permits quantification of myocardial blood flow. However, perfusion-CMR has only been validated in a small number of previous studies and using relatively early perfusion methods. An isolated blood-perfused MR compatible porcine heart model which can be imaged by identical equipment used for humans has been recently proposed. The model permits full control of regional myocardial blood flow, thus providing a valuable tool for the validation of quantitative perfusion assessment. 9 perfusion experiments were performed in male white cross landrace pigs (54±6 kg). Hearts were harvested under terminal anaesthesia and transported to the laboratory under cold cardioplegic arrest. After reperfusion the coronary flow rate was set by an external pump to accommodate stable sinus rhythm. Myocardial blood flow of 0.8 ml/min/g was considered normal reference flow of 100%. Hearts were positioned in a clinical 1.5 Tesla MR Scanner (Philips Achieva) and myocardial perfusion CMR was performed with a k-t SENSE accelerated high-resolution balanced Turbo Field Echo pulse sequence yielding a spatial resolution of 1.7x1.9x10 mm. Perfusion-CMR was performed using a dual bolus scheme (5 ml of neat (7mmol/l) and 5 ml of dilute (0.7 mmol/l) gadobutrolum, Gadovist, Schering, Berlin, Germany) and quantified using Fermi function constrained deconvolution. Values were expressed as Mean±SD per slice (6 region of interests) and compared with the known coronary flow rate. Hearts remained stable during isolated coronary perfusion and thus experiments were successfully conducted. Mean myocardial blood flow of the external pump was set to 96±33%. There was good correlation with mean myocardial perfusion as assessed by CMR (95±38%) using simple linear regression analysis (r=0.95, mean difference 0.35%, limits of agreement +24.43% and -23.74%). Figure 1 shows the quantitative result of each experiment in regard to the externally set blood flow. Relation between [%] Myocardial Blood Flow given by the infusion pump and [%] Blood Flow derived from magnetic resonance perfusion imaging (Fermi deconvolution). Quantitative assessment of myocardial perfusion using CMR correlates well with known myocardial blood flow in an isolated porcine heart model. Further studies using fluorescently labelled microspheres as the gold-standard are required to confirm this finding.
No takes yet. Share an insight, caveat, or question.
Schuster et al. (2011) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: