The electrical cleanup of helium on molybdenum surfaces has been investigated. In this case, the phenomenon can be described by a trapping of ions upon impact with the surface. Measurements of the trapping efficiency η (atoms removed/ions collected) have been made over a range of ion energies from 150 to 2600 ev. The re-emission of trapped helium atoms was investigated in detail. The contribution of re-emission to the pumping process is described by a phenomenological theory. The results indicate that the trapping efficiency is lowered by a short time re-emission of trapped atoms. Through the long-time re-emission of atoms, the theory accounts quantitatively for the observed saturation of the cleanup process.
No takes yet. Share an insight, caveat, or question.
Varnerin et al. (1957) studied this question.