Comparing a direct radioimmunoassay for 6-sulfatoxymelatonin (aMT6s) with an established gas chromatographic/mass spectrometric method for 6-hydroxymelatonin, we found a good correlation r = 0.94 (P less than 0.001, n = 100). aMT6s was stable, both in urine and plasma samples, without preservative, for at least two years at -20 degrees C and for five days at room temperature. Urinary excretion of aMT6s showed considerable inter-individual differences; however, the aMT6s excretion of any one individual was consistent over a four-day period, as assessed by continuous collection from 18 normal volunteers. Total 24-h urinary excretion of aMT6s was significantly correlated with the area under the curve of the respective profiles for plasma melatonin (r = 0.75, P = 0.0002) and plasma aMT6s (r = 0.70, P = 0.0005) for 22 healthy volunteers. At 24:00 h and 03:00 h, sampling plasma at 30-s intervals provided no evidence for episodic secretion (in short pulses) of either melatonin or aMT6s.
No takes yet. Share an insight, caveat, or question.
Bojkowski et al. (1987) studied this question.