Why the study?
Does GEDVI by PiCCO or CEDVI by PAC better correlate with transoesophageal echocardiography for assessing left ventricular preload changes after fluid replacement in cardiac surgery patients?
Does GEDVI by PiCCO or CEDVI by PAC better correlate with transoesophageal echocardiography for assessing left ventricular preload changes after fluid replacement in cardiac surgery patients?
GEDVI assessed by the PiCCO system correlates better with echocardiographic changes in left ventricular preload following fluid replacement than CEDVI measured by a modified pulmonary artery catheter.
Answers are grounded in this paper and cite their sources.
PiCCO GEDVI may better inform preload assessment than PAC CEDVI in cardiac surgery; hypothesis-generating and requires randomized confirmation before practice change.
BACKGROUND: End-diastolic volume indices determined by transpulmonary thermodilution and pulmonary artery thermodilution may give a better estimate of left ventricular preload than pulmonary capillary wedge pressure monitoring. The aim of this study was to compare volume preload monitoring using the two different thermodilution techniques with left ventricular preload assessment by transoesophageal echocardiography (TOE). METHODS: Twenty patients undergoing elective cardiac surgery with preserved left-right ventricular function were studied after induction of anaesthesia. Conventional haemodynamic variables, global end-diastolic volume index using the pulse contour cardiac output (PiCCO) system (GEDVI(PiCCO)), continuous end-diastolic volume index (CEDVI(PAC)) measured by a modified pulmonary artery catheter (PAC), left ventricular end-diastolic area index (LVEDAI) using TOE and stroke volume indices (SVI) were recorded before and 20 and 40 min after fluid replacement therapy. Analysis of variance (Bonferroni-Dunn), Bland-Altman analysis and linear regression were performed. RESULTS: GEDVI(PiCCO), CEDVI(PAC), LVEDAI and SVI(PiCCO/PAC) increased significantly after fluid load (P<0.05). An increase >10% for GEDVI(PiCCO) and LVEDAI was observed in 85% and 90% of the patients compared with 45% for CEDVI(PAC). Mean bias (2 SD) between percentage changes (delta) in GEDVI(PiCCO) and deltaLVEDAI was -3.2 (17.6)% and between deltaCEDVI(PAC) and deltaLVEDAI -8.7 (30.0)%. The correlation coefficient (r2) for deltaGEDVI(PiCCO) vs deltaLVEDAI was 0.658 and for deltaCEDVI(PAC) vs deltaLVEDAI 0.161. The relationship between deltaGEDVI(PiCCO) and deltaSVI(PiCCO) was stronger (r2=0.576) than that between deltaCEDVI(PAC) and deltaSVI(PAC) (r2=0.267). CONCLUSION: GEDVI assessed by the PiCCO system gives a better reflection of echocardiographic changes in left ventricular preload, in response to fluid replacement therapy, than CEDVI measured by a modified PAC.
No takes yet. Share an insight, caveat, or question.
Hofer et al. (2005) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: