Why the study?
Does transpulmonary arterial thermodilution using a long radial artery catheter accurately measure cardiac output compared to pulmonary artery thermodilution in patients who have undergone coronary artery surgery?
Does transpulmonary arterial thermodilution using a long radial artery catheter accurately measure cardiac output compared to pulmonary artery thermodilution in patients who have undergone coronary artery surgery?
Transpulmonary arterial thermodilution using a centrally sited long radial artery catheter provides cardiac output measurements interchangeable with those from a pulmonary artery catheter in post-cardiac surgery patients.
May support less invasive cardiac output monitoring post-cardiac surgery; leaves open prospective validation before clinical adoption.
Cardiac output can be measured accurately by transpulmonary arterial thermodilution using the PiCCO (Pulsion Medical Systems, Munich, Germany) system with a femoral artery catheter. We have investigated the accuracy of a new 50 cm 4 French gauge radial artery catheter and the ability to use the system with a shorter radial catheter. We studied 18 patients who had undergone coronary artery surgery and made three simultaneous measurements of cardiac output by arterial thermodilution and with a pulmonary artery catheter. The radial catheter was withdrawn in 5 cm increments and the measurements were repeated. We found close agreement between arterial thermodilution and pulmonary artery thermodilution with a mean (SD) bias of 0.38 (0.77) l x min(-1). Arterial thermodilution became unreliable once the catheter had been withdrawn by more than 5 cm. We conclude that cardiac output measurement with arterial thermodilution with a radial catheter is interchangeable with that derived from a pulmonary artery catheter, and that a centrally sited arterial catheter is required for accurate determination of cardiac output by transpulmonary arterial thermodilution.
No takes yet. Share an insight, caveat, or question.
Orme et al. (2004) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: