Key result
Arterial thermodilution accurately measured cardiac output compared to pulmonary artery thermodilution.
Why the study?
Does the arterial thermodilution technique accurately measure cardiac output compared to pulmonary artery thermodilution in an animal model of hypovolemic shock?
Does the arterial thermodilution technique accurately measure cardiac output compared to pulmonary artery thermodilution in an animal model of hypovolemic shock?
Arterial thermodilution provides accurate cardiac output measurements comparable to pulmonary artery thermodilution even during low cardiac output states like severe bleeding and shock.
Answers are grounded in this paper and cite their sources.
Supports arterial thermodilution for CO monitoring in animal hypovolemic shock; hypothesis-generating for human translation.
Background and objective: The arterial thermodilution technique offers the ability to measure cardiac output using only central venous and arterial catheters. However, the technique has been reported to overestimate cardiac output because of a higher loss of cold indicator due to the increased distance between the sites of injection and measurement. In this study, the two techniques were compared with respect to conditions of low cardiac output in which a longer passage time may further increase loss of indicator. Methods: Seventeen anaesthetized dogs were studied during hypovolaemic shock and fluid resuscitation. Cardiac output measurements were carried out simultaneously by arterial and pulmonary artery thermodilution techniques. Results: One-hundred-and-two measurements were performed. The mean cardiac output was 2.28 ± 1.4 L min−1 by the pulmonary arterial technique and 2.29 ± 1.56 L min−1 by the arterial thermodilution technique. The correlation coefficient between the two measurements was 0.95, the precision −0.04 ± 0.41 L min−1 and the limits of agreement from −0.86 to 0.78 L min−1. The agreement was also consistent at low cardiac outputs. Conclusions: The arterial thermodilution technique may serve as a less invasive cardiac output monitor in conditions of severe bleeding and shock.
No takes yet. Share an insight, caveat, or question.
Friedman et al. (2002) studied hypovolaemic shock and fluid resuscitation (n=17). Arterial thermodilution technique vs. Pulmonary artery thermodilution technique was evaluated on Cardiac output (correlation coefficient 0.95). Arterial thermodilution accurately measured cardiac output compared to pulmonary artery thermodilution.
Synapse has enriched 10 related papers. Consider them for comparative context: