Answers are grounded in this paper and cite their sources.
The estimated diffusion coefficients for nitric oxide and carbon monoxide in human plasma and red cells can be inserted into the equations for Fick’s 1st and 2nd laws. The surface area of the alveolar membrane and exposed red cells can then be calculated from D LNO and D LCO (in hyperoxia). This yields a value of 18.7 m 2 for alveolar capillary membrane via D LNO , 19.6 m 2 for red cell surface area via D LCO in a seated human at rest and = 2.03m 2 for a membrane oxygenator. The values for a seated human are substantially less than morphometric values. This is likely due to a considerable functional reserve in the lung. • The diffusion coefficients for NO and CO in plasma and red cells can be used in Fick’s 1st and 2nd laws. • The membrane and red cell surface area can be calculated from D LNO and D LCO (in hyperoxia). • The values for a seated human are less than morphometric. This is likely due to a functional reserve in the lung.
No takes yet. Share an insight, caveat, or question.
Colin Borland (2025) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: