An asymmetric inverter features different dc-link voltages for each power cell and depending on the dc voltage ratios, there are binary, trinary, etc., asymmetric topologies. In particular, the trinary one can provide a waveform with 3n levels, where n is the number of cells connected in cascade. Hence, for n = 3, an output voltage with 27 levels can be obtained, ensuring a low total harmonic distortion (THD) and reduced dv/dt. However, when the load consumes active power, some power cells of the inverter can operate in regeneration mode, complicating the topology and control. To overcome this problem, a new modulation method for asymmetric inverters is presented. It features an ac output voltage of 13 levels for n = 3, and ensures unidirectional power flow in every power cell. This new modulation method also provides a voltage waveform with low dv/dt and reduced THD (5.7%). To confirm the approach, power flow and sensitivity analysis to changes in the dc voltage ratios are performed. Finally, simulation and experimental results are provided.
No takes yet. Share an insight, caveat, or question.
Espinosa et al. (2013) studied this question.