Answers are grounded in this paper and cite their sources.
In this paper, a repetitive-based controller for the compensation of 6 lscr plusmn 1 harmonic components is proposed. This control scheme is more appropriate for processes that involve the use of six-pulse converters or other converters that mainly produce harmonic components at those frequencies. The control scheme is based on the feedback array of two delay lines plus a feedforward path that compensates only the 6 lscr plusmn 1 multiples of the fundamental frequency, thereby reducing the possibility of reinjecting unnecessary distortion into the system. The proposed scheme is, then, plugged into a generic feedback control system where a stability analysis is carried out. In addition, the passivity properties of the proposed scheme are presented, which open the possibility of control design following the passivity-based approach. Experiments that are based on a simple digital implementation are provided to illustrate the merits of our solution. These results include the open-loop responses of the proposed scheme and the responses in a practical example to validate its effectiveness in an application. For this latter result, the proposed scheme has been used in the controller of a 2-kVA shunt active filter to compensate the current harmonic distortion.
No takes yet. Share an insight, caveat, or question.
Escobar et al. (2008) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: