Key result
Pre-procedural risk mitigation with ECMO backup enables successful TAVR in a 97-year-old, lowering mean gradient to 8 mmHg.
Why the study?
TAVR in nonagenarians with extensive aortic valve calcification carries a substantial risk of intraprocedural circulatory collapse.
Case Report (n=1)
No
A structured pre-procedural risk mitigation strategy, including a balloon-expandable valve and proactive ECMO backup, enabled successful TAVR and management of circulatory collapse in an extreme-risk 97-year-old patient.
Hypothesis-generating for ECMO-backed TAVR in extreme-risk nonagenarians; prospective studies needed before wider adoption.
Transcatheter aortic valve replacement (TAVR) in nonagenarians with extensive aortic valve calcification is associated with a substantial risk of intraprocedural circulatory collapse. This case report describes a structured pre-procedural risk mitigation strategy integrating a balloon-expandable valve system and a pre-emptive, “wet-prepared” extracorporeal membrane oxygenation (ECMO) backup. A 97-year-old man with severe symptomatic aortic stenosis (peak velocity = 4.76 m/s; aortic valve calcium volume = 1178 mm³) underwent transfemoral TAVR using a structured approach incorporating precision imaging, careful device selection using a domestic Chinese balloon-expandable valve system (Prizvalve ® TAV23), proactive ECMO preparedness, and multidisciplinary team coordination. Immediately after valve deployment, the patient developed circulatory collapse (blood pressure = 40/20 mmHg). A predefined emergency protocol was promptly activated. Following chest compressions, vasopressor administration, and pacing optimization, spontaneous circulation was restored within minutes. Angiography confirmed stable valve positioning with satisfactory expansion. At 3-month follow-up, echocardiography demonstrated absence of paravalvular leakage and preserved left ventricular systolic function. This case demonstrates the feasibility of a structured, pre-procedural risk mitigation strategy for TAVR in an exceptionally high-risk patient. The approach enabled the management of intraprocedural circulatory collapse. In this setting, the balloon-expandable valve platform demonstrated procedural characteristics that were well suited for this complex anatomy.
No takes yet. Share an insight, caveat, or question.
Hong et al. (2026) conducted a case report in Severe symptomatic aortic stenosis (n=1). Transcatheter aortic valve replacement (TAVR) with a balloon-expandable valve and proactive ECMO backup was evaluated on Procedural success and hemodynamic improvement. A structured pre-procedural risk mitigation strategy using a balloon-expandable valve and proactive ECMO backup enabled successful TAVR in a 97-year-old man, reducing the mean transvalvular gradient from 54 mmHg to 8 mmHg at 3 months.