Why the study?
Does balloon-expandable TAVR result in lower device success and higher complication rates in patients with extremely calcified aortic valves compared to those with less calcification?
Does balloon-expandable TAVR result in lower device success and higher complication rates in patients with extremely calcified aortic valves compared to those with less calcification?
Balloon-expandable TAVR in patients with extremely calcified aortic valves (>8,000 Agatston Units) is associated with lower device success and a greater risk of paravalvular regurgitation.
May warrant caution with balloon-expandable TAVR in extreme calcification; leaves open optimal device selection pending prospective data.
OBJECTIVES: To assess the procedural and short-term clinical outcome of performing balloon-expandable TAVR in patients with extremely calcified aortic valves. BACKGROUND: Quantity of aortic valve calcification predicts rates of paravalvular regurgitation (PVR) post transcatheter aortic valve replacement (TAVR). Nonetheless, short-term outcomes of balloon-expandable TAVR in patients with extremely high calcified aortic valves have not been previously described. METHODS: We studied patients with severe aortic stenosis that underwent balloon-expandable TAVR and had a pre-procedural non-contrast CT. Twenty patients that had aortic valve calcification score (AVCS) of more than 8,000 Agatston Units were compared to 279 patients with lower calcification scores. TAVR endpoints, device success and adverse events were considered according to the Valve Academic Research Consortium-2 definitions. RESULTS: Device success was 80% in the extremely high calcification group compared to 95.3% in patients with less calcified aortic valves (P = 0.004). There was significantly more postprocedural PVR in the extreme calcification group: 50%, 35%, 10%, 5% vs. 72.4%, 25.8%, 1.8%, 0% for no/trace, mild, moderate and severe PVR, respectively (P < 0.001). There was one case of ascending aortic perforation resulting in intramural hematoma that resolved with no treatment. In-hospital mortality, new pacemaker implantation and major complications were similar between groups. CONCLUSIONS: Balloon-expandable TAVR in patients with extremely calcified aortic valve is associated with lower device success and greater risk of PVR.
No takes yet. Share an insight, caveat, or question.
Abramowitz et al. (2015) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: