Key result
Heart rate and deceleration time predict transmitral E/A-wave overlap to estimate target heart rate.
Why the study?
Heart rate reduction therapy is widely used in systolic heart failure, but the optimal target heart rate remains controversial.
Can echocardiographic deceleration time and heart rate predict the optimal target heart rate with zero E-wave and A-wave overlap in patients with systolic heart failure?
Cohort (n=368)
Sonographers blinded to study protocol
Can echocardiographic deceleration time and heart rate predict the optimal target heart rate with zero E-wave and A-wave overlap in patients with systolic heart failure?
A novel echocardiography-based formula utilizing deceleration time may estimate the ideal target heart rate to optimize left ventricular filling in patients with systolic heart failure.
May inform individualized heart rate targets in systolic HF via echocardiography; leaves open prospective validation before clinical use.
AIMS: Heart rate reduction therapy using ivabradine, a selective inhibitor of the funny current of the sinoatrial node, is widely used in the systolic heart failure cohort. However, the optimal target of heart rate remains controversial. The association between heart rate and 'overlap' between E-wave and A-wave in the pulse wave transmitral flow Doppler echocardiography might be a key to find the ideal heart rate in each individual. METHODS AND RESULTS: We performed transthoracic echocardiography in patients with systolic heart failure, and the association between heart rate, deceleration time, and overlap length between E-wave and A-wave was assessed. In total, 368 patients with systolic heart failure (median 76 years old, 190 men, median ejection fraction 40%) were included. The measured overlap length was 35 (-72, 115) ms. Given the results of multiple linear regression analyses, we constructed a formula: estimated overlap length (ms) = -589 + 6.2 × heart rate (bpm) + 0.81 × deceleration time (ms), which had a good agreement with actually measured one (r = 0.62). The ideal heart rate, at which the overlap length is 'zero' and probably cardiac output is maximized, is calculated as follows: ideal heart rate (bpm) = 93 - 0.13 × deceleration time (ms). CONCLUSIONS: We proposed a novel formula using deceleration time to estimate ideal heart rate that achieves a zero overlap between E-wave and A-wave in patients with systolic heart failure. Prognostic impact of the formula-guided heart rate optimization should be studied.
No takes yet. Share an insight, caveat, or question.
Izumida et al. (2020) conducted a cohort in Systolic heart failure (HFrEF) (n=368). Heart rate and deceleration time was evaluated on Correlation between estimated and measured overlap length of transmitral E-wave and A-wave (r = 0.62, p=<0.001). Heart rate and deceleration time independently determined transmitral E-wave and A-wave overlap length, yielding a formula to estimate an individual's ideal target heart rate (r=0.62, p<0.001).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: