Key result
Beta-blocker therapy was underutilized in heart failure patients undergoing cardiac device procedures, with 33.4% lacking a prescription beforehand and use increasing to 83.4% post-procedure.
Why the study?
What is the rate of beta-blocker utilization before and after cardiac device procedures in patients with heart failure?
Cohort (n=2,766)
Yes
What is the rate of beta-blocker utilization before and after cardiac device procedures in patients with heart failure?
A significant proportion of heart failure patients do not receive optimal beta-blocker therapy prior to primary prevention ICD/CRT implantation, indicating a gap in guideline-directed medical therapy.
Signals pre-procedural GDMT gap in HF device patients; hypothesis-generating for interventions to improve beta-blocker use and outcomes.
BACKGROUND: Current guidelines emphasize the need for optimal medical therapy before implantation of cardiac devices (implantable cardioverter-defibrillator, cardiac resynchronization therapy). Our objective was to evaluate use of beta-blockers (BB) among patients with heart failure undergoing a cardiac device procedure. METHODS AND RESULTS: We used a large, multistate, managed-care database (January 2003 to December 2006) to identify adults admitted with an International Classification of Diseases, Ninth Revision (ICD-9) procedure code for cardiac device, continuous enrollment for 180 days before and 180 days after device procedure, and a primary or secondary ICD-9 diagnosis code for heart failure during that period. Our primary measures were use of BB before device procedure and changes after discharge. A total of 2766 beneficiaries (78.8% men; median age, 61 years) underwent a device procedure for primary prevention. The median number of days on BB therapy in the 90 days before device procedure was 46. Beneficiaries who did not have a pharmacy fill for BB during that time (n=925, 33.4%) were more elderly and had fewer antecedent outpatient visits with a cardiologist. There was a shift toward greater use of BB after device procedure; 83.4% had at least 1 pharmacy fill for a BB during follow-up. CONCLUSIONS: BB are underused before and after cardiac device procedures. There is a modest increase in use after the procedure. Strategies are required to ensure that patients are on optimal medical therapy before device therapy is selected.
No takes yet. Share an insight, caveat, or question.
Hauptman et al. (2010) conducted a cohort in Heart failure undergoing a cardiac device procedure (n=2,766). Beta-blocker therapy was evaluated on Use of beta-blockers before device procedure and changes after discharge. Beta-blocker therapy was underutilized in heart failure patients undergoing cardiac device procedures, with 33.4% lacking a prescription beforehand and use increasing to 83.4% post-procedure.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: