Why the study?
How can clinical parameters, fluoroscopy, and echocardiography distinguish pannus from thrombus in mechanical valve obstruction?
Population
A patient with a St. Jude tricuspid valve obstruction (n=1)
Design
Case_report
Authors
Loading...
Thrombolysis may fail if pannus causes obstruction; this case report leaves open reliable noninvasive distinction from thrombus.
How can clinical parameters, fluoroscopy, and echocardiography distinguish pannus from thrombus in mechanical valve obstruction?
This case highlights the importance of using clinical parameters, fluoroscopy, and echocardiography to accurately distinguish between pannus and thrombus in prosthetic valve obstruction to guide appropriate therapy.
Licata et al. (2002) studied this question.