This paper presents theoretical and experimental discussions on a practical speed-sensorless start-up method for an induction motor driven by a modular multilevel cascade inverter based on double-star chopper cells (MMCI-DSCC) from standstill to middle speed. This motor drive is suitable, particularly for a large-capacity fan- or blower-like load. The load torque is proportional to a square of the motor mechanical speed. The start-up method is characterized by combining capacitor-voltage control with motor-speed control. The motor-speed control with the minimal stator current plays a crucial role in eliminating a speed sensor from the drive system and in reducing an ac-voltage fluctuation occurring across each dc capacitor. Experimental results obtained from the 400-V 15-kW downscaled system with no speed sensor verify that the motor-speed control proposed for the DSCC-based drive system can enhance the start-up torque by a factor of three under the same ac-voltage fluctuation. Several start-up waveforms show stable performance from standstill to middle speed with different load torques.
No takes yet. Share an insight, caveat, or question.
Okazaki et al. (2014) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: