Isorhythmic A-V dissociation presents in two distinct ECG patterns, with one driven by a biologic feedback control system involving stroke volume, blood pressure, and the baroreceptor reflex.
Answers are grounded in this paper and cite their sources.
May aid ECG differentiation of isorhythmic AV dissociation; leaves open pattern II mechanism and requires prospective validation.
The electrocardiographic patterns recorded from seven patients with isorhythmic A-V dissociation fall into two distinct groups. In pattern I, the P wave fluctuates cyclically back and forth across the QRS complex. The mechanism responsible for this type of A-V synchronization represents a typical biologic feedback control system. The P-R interval is a determinant of stroke volume, which in turn influences the arterial blood pressure. The blood pressure has an inverse effect on the discharge frequency of the S-A node through the baroreceptor reflex. The S-A nodal frequency then affects the P-R interval, to close the feedback loop. In pattern II, the P wave is in a fairly constant position relative to the QRS complex. It is usually coincident with the QRS complex or appears on the ST segment or first half of the T wave. The mechanism producing synchronization in pattern II type of isorhythmic dissociation has not been established conclusively.
No takes yet. Share an insight, caveat, or question.
Levy et al. (1970) studied this question.