Why the study?
Pacemaker-dependent patients undergoing CIED extraction often require temporary pacing, prompting an evaluation of the safety and utility of leadless pacing compared to externalized temporary pacing.
Does a leadless pacing system reduce hospital length of stay and complications compared to temporary externalized pacing in pacemaker-dependent patients following CIED extraction?
Does a leadless pacing system reduce hospital length of stay and complications compared to temporary externalized pacing in pacemaker-dependent patients following CIED extraction?
In pacemaker-dependent patients undergoing CIED extraction without active bacteremia, immediate implantation of a leadless pacemaker significantly reduces hospital length of stay compared to temporary externalized pacing, with similar safety outcomes.
Answers are grounded in this paper and cite their sources.
May shorten hospitalization versus temp-perm in select PD extraction cases; leaves open prospective trials for confirmation.
Pacemaker-dependent (PD) patients undergoing implantable cardiac electronic device extraction often must be subjected to temporary pacing interventions. We sought to determine the safety and utility of a leadless pacing system (Micra™; Medtronic, Minneapolis, MN, USA) in patients undergoing system extraction as compared with externalized temporary transvenous right ventricular lead (temp-perm) placement. We performed a retrospective cohort analysis of all patients receiving either permanent Micra™ or temp-perm systems following system extraction from October 2013 to September 2017 at Vanderbilt University Hospital. The Micra™ and temp-perm cohorts included nine and 27 patients meeting the inclusion criteria, respectively. System infection was the most common indication for extraction (67% Micra™, 84% temp-perm), but no patients had active bacteremia at the time of permanent system reimplantation. There was no difference in system type (p = 0.09) or mean lead dwell time extracted (109 versus 81 months; p = 0.93). Procedure times were comparable between the two groups (180 versus 194 minutes; p = 0.74). Patients receiving Micra™ systems had shorter hospital stays after extraction (two versus eight days; p < 0.005), with no difference in major complications (11% versus 15%; p = 0.78) or 30-day (11% versus 7%; p = 0.77) or 90-day (11% versus 11%; p = 0.45) mortality. No reinfections were observed in either group at 90 days. Implantation of the Micra™ pacing system in select PD patients after system extraction is feasible and appears to reduce the hospital length of stay as compared with the use of temp-perm systems.
No takes yet. Share an insight, caveat, or question.
Gonzales et al. (2019) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: