Answers are grounded in this paper and cite their sources.
The continual application of renewable cellulose nanoparticles has led to several advancements in their performance as a reinforcing component for the fabrication of high-performance additively manufactured nanocomposite products. Nonetheless, incorporating hydrophilic cellulose nanocrystals into hydrophobic thermoplastics, such as polylactic acid and thermoplastic urethane, remains a substantial challenge for achieving successful and smooth compatibility as an additional component in 3D-printed composites. This study has successfully investigated the effects of chemically modified cellulose nanocrystals at concentrations of 0.05%, 1%, and 3% when blended with hexadecyltrimethylammonium bromide and polylactic acid-thermoplastic urethane (PLA-TPU) at an 80:20 ratio. This study demonstrates the use of a fused deposition modeling (FDM) printer to manufacture 3D-printed PLA-TPU-CNC (cellulose nanocrystal) composites through additive manufacturing. The composite with 0.05% modified CNC exhibits 19.12 MPa higher tensile strength and 58.3% higher flexural strength than the unmodified one. Furthermore, the PLA-TPU blend with 1% modified CNC obtained the highest Izod impact strength, 63.43 MPa. The 3D-printed composite with 1% modified CNC displayed significantly better compressive strength than other modified variations and concentrations in the unmodified group. Composites with 1% unmodified CNC exhibited 2.33% higher heat deflection than blended PLA-TPU. The composites with 0.05% modified CNC showed an increase of 1.12% compared to the PLA-TPU blend and a modest increase of up to 2.71% compared to the other modified CNC concentrations. The composite with 1% modified CNC was superior to all the variations in terms of hardness, with a 29.6% increase above the 1% unmodified composite. The utilization of cationic surfactants, such as hexadecyltrimethylammonium bromide (HDTMA-Br), enhances CNC infiltration, interfacial adhesion, and hydrophobicity control, thereby improving the mechanical performance of the composites and making them suitable for specific medical and engineering material designs and applications. The F-statistics for all concentration levels yielded a ratio substantially greater than the F-critical value, and the p-value was considerably less than 0.05, indicating a significant and favorable design criterion.
No takes yet. Share an insight, caveat, or question.
Maglalang et al. (2025) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: