This is the authors' abstract. We don't add key points for this paper.
, providing a 50-fold improvement in throughput compared to previously demonstrated acoustofluidic approaches. The device consists of a robust silicon based micro-mechanical oscillator, sandwiched between two polymeric channels which guide the fluids in and out of the system. The chip is actuated by application of an oscillatory electrical signal onto a piezoelectric disk coupled to the substrate by adhesive. At the optimal frequency, this acoustofluidic system can homogenise two fluids with a relative mixing efficiency of 91%, within 4.1 ms from first contact. The micromixer has been used to synthesize two different systems: Budesonide nanodrugs with an average diameter of 80 ± 22 nm, and DNA nanoparticles with an average diameter of 63.3 ± 24.7 nm.
Answers are grounded in this paper and cite their sources.
No takes yet. Share an insight, caveat, or question.
Le et al. (2019) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: